Abstract
Objectives To evaluate the improved diagnostic efficacy of the emerging non-invasive microstructure imaging technique, MR cytometry, in differentiating benign and malignant prostate lesions, after removing perfusion effect and introducing histogram features. Methods This study included 33 patients with prostate cancer and 39 patients with benign lesions, who underwent time-dependent diffusion MRI examinations, including pulsed gradient spin-echo (PGSE) diffusion-weighted imaging (DWI) and oscillating gradient spin-echo (OGSE) DWI at frequencies of 20 Hz and 40 Hz. A mono-exponential signal-fitting method was used to eliminate perfusion effects. Apparent diffusion coefficients (ADC), MR-cytometry-derived microstructural parameters (cell diameter \(\:\text{d}\), intracellular volume fraction \(\:{\text{v}}_{\text{i}\text{n}}\), extracellular diffusivity \(\:{D}_{ex}\) and cellularity \(\:{\uprho\:}\)) and corresponding histogram features were calculated to differentiate lesions. Mann-Whitney U-tests were used to evaluate the differences between benign and malignant lesions. Uni- and multi-variate logistic regressions were performed and calculated the area under the receiver operating characteristic (AUC) to quantify the diagnostic performance of classifiers. Results Removal of perfusion effect improved the significance level of the difference in the cell diameter \(\:d\) (from \(\:\text{p}>0.05\) to \(\:\text{p}<0.01\)), where \(\:\text{d}\) is larger in the benign group. The diagnostic efficacy of a single histogram feature was comparable to that of the corresponding ADC or microstructural parameter mean value. Both removing perfusion effect and incorporating histogram features can improve the AUC of the combined regression models (from 0.885 to 0.918 and 0.908, respectively). Combining both strategies further enhanced the AUC to 0.934. Conclusion In MR cytometry analysis, removing the perfusion effect and incorporating histogram features of ADCs and microstructural parameters can provide better diagnostic efficacy.
Keywords
Funding Information
- Postdoctoral Fellowship Program of CPSF (GZC20230305)
- Peking Union Medical College Hospital Talent Cultivation Program (UHB11588)
- National science Foundation of China-Youth Fund (2024-NSFC-62401329)
- Natural Science Foundation of Beijing Municipality (L232133)
- Chinese Academy of Medical Sciences Initiative for Innovative Medicine (2025-I2M-C&T-C-001)
This publication has 35 references indexed in Scilit:
- Time-Dependent Diffusion MRI for Quantitative Microstructural Mapping of Prostate CancerRadiology, 2022
- Pulsed and oscillating gradient MRI for assessment of cell size and extracellular space (POMACE) in mouse gliomasNMR in Biomedicine, 2016
- Impact of transcytolemmal water exchange on estimates of tissue microstructural properties derived from diffusion MRIMagnetic Resonance in Medicine, 2016
- Quantification of cell size using temporal diffusion spectroscopyMagnetic Resonance in Medicine, 2015
- Radiomics: Extracting more information from medical images using advanced feature analysisEuropean Journal of Cancer, 2012
- Investigation of prostate cancer using diffusion-weighted intravoxel incoherent motion imagingMagnetic Resonance Imaging, 2011
- New Insights into Tumor Microstructure Using Temporal Diffusion SpectroscopyCancer Research, 2008
- Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 2002
- Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging: a modest proposal with tremendous potential.Radiology, 1988
- MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders.Radiology, 1986