Mechanical Design Optimization of Bioabsorbable Fixation Devices for Bone Fractures
Authors:
- Scott T. LovaldSLScott T. Lovald
- Tariq KhraishiTKTariq Khraishi
- Jon WagnerJWJon Wagner
- Bret BaackBBBret Baack
- 1 March 2009
- journal article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 20 (2) , 389-398
Abstract
Bioabsorbable bone plates can eliminate the necessity for a permanent implant when used to fixate fractures of the human mandible. They are currently not in widespread use because of the low strength of the materials and the requisite large volume of the resulting bone plate. The aim of the current study was to discover a minimally invasive bioabsorbable bone plate design that can provide the same mechanical stability as a standard titanium bone plate. A finite element model of a mandible with a fracture in the body region is subjected to bite loads that are common to patients postsurgery. The model is used first to determine benchmark stress and strain values for a titanium plate. These values are then set as the limits within which the bioabsorbable bone plate must comply. The model is then modified to consider a bone plate made of the polymer poly-L/DL-lactide 70/30. An optimization routine is run to determine the smallest volume of bioabsorbable bone plate that can perform and a titanium bone plate when fixating fractures of this considered type. Two design parameters are varied for the bone plate design during the optimization analysis. The analysis determined that a strut style poly-L-lactide-co-DL-lactide plate of 690 mm2 can provide as much mechanical stability as a similar titanium design structure of 172 mm2. The model has determined a bioabsorbable bone plate design that is as strong as a titanium plate when fixating fractures of the load-bearing mandible. This is an intriguing outcome, considering that the polymer material has only 6% of the stiffness of titanium.Keywords
This publication has 29 references indexed in Scilit:
- Effect of fracture healing on the fixation of a parasymphyseal mandibular fracture: a study using the finite element methodInternational Journal of Biomedical Engineering and Technology, 2007
- Comparison of Plate-Screw Systems Used in Mandibular Fracture Reduction: Finite Element AnalysisJournal of Biomechanical Engineering, 2006
- Symptomatic Plate Removal in Maxillofacial TraumaAnnals of Plastic Surgery, 2005
- Variations in cortical material properties throughout the human dentate mandibleAmerican Journal of Physical Anthropology, 2003
- Modeling the Mechanical Behavior of the Jaws and Their Related Structures By Finite Element (Fe) AnalysisCritical Reviews in Oral Biology & Medicine, 1997
- Three‐dimensional finite element stress analysis of the dentate human mandibleAmerican Journal of Physical Anthropology, 1992
- Modeling the biomechanics of the mandible: A three-dimensional finite element studyJournal of Biomechanics, 1992
- Determination of stress levels and profiles in the periodontal ligament by means of an improved three-dimensional finite element model for various types of orthodontic and natural force systemsJournal of Biomedical Engineering, 1991
- Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forcesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1987
- The mechanical characteristics of cancellous bone at the upper femoral regionJournal of Biomechanics, 1983