A distinguishable observation between survival and success rate outcome of hydroxyapatite‐coated implants in 5–10 years in function
Authors:
- 16 September 2005
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 17 (1) , 85-93
Abstract
Purpose: To differentiate between the survival and success definitions of functional hydroxyapatite (HA)‐coated implant prosthesis.Methods: A total of 248 implants (62 patients), 5–10 years in function, were evaluated. The implant distribution length was 8 mm (6.5%), 10 mm (29.4%), 13 mm (30.2%) and 15 mm (33.9%). The diameter was 3.25 mm (60.1%) and 4 mm (39.9%). Probing depth (PD), gingival index (GI), height of keratinized mucosa (KM) and recession (REC) were measured. Periapical radiographs were taken to estimate the amount of crestal bone resorption (BL), mesially and distally, with the aid of a millimetric‐scaled magnifying glass (× 8). Only implants that fulfilled the success rate criteria were considered as successful. All other functional implants were assigned to the non‐successful group. All functional implant prostheses were defined as survival ones.Results: The accumulative survival rate after 5 and 10 years was 94.4% and 92.8%, respectively. Accumulative success rates were 89.9% and 54%, respectively. Implants 13 and 15 mm in length (97.9% and 96.4%, respectively) had the highest survival rate, which was higher over implants 8 and 10 mm in length (75%, PP=0.019). The average BL was 1.7, 0.92 and 2.79 mm for the survival, successful and non‐successful defined implant groups. PD was 3.26, 2.79 and 4 mm and GI was 0.96, 0.75 and 1.57, respectively. These measurements were statistically different between implant groups. KM and REC measurements showed similar scoring for all groups. A correlation was shown between successful and non‐successful implants on the score of GI and PD (PConclusion: A distinguishable observation between survival and success rate was noted particularly in long‐term observations. Implant length and diameter have an influence on the survival rate. Clinical parameter scores expressed an influence on the defined implant status.Keywords
This publication has 50 references indexed in Scilit:
- Tissue reactions adjacent to well-fixed hydroxyapatite-coated acetabular cupsThe Journal of Bone and Joint Surgery. British volume, 2003
- Stability of the Bone‐Implant Complex. Results of Longitudinal Testing to 60 Months With the Periotest Device on Endosseous Dental ImplantsAnnals of Periodontology, 2000
- Three‐Year Post‐Placement Survival of Implants Mobile at PlacementAnnals of Periodontology, 2000
- A Prospective Multicenter Clinical Trial Comparing One‐ and Two‐Stage Titanium Screw‐Shaped Fixtures with One‐Stage Plasma‐Sprayed Solid‐Screw FixturesClinical Implant Dentistry and Related Research, 2000
- A 5‐year prospective clinical and radiographic study of non‐submerged dental implantsClinical Oral Implants Research, 2000
- A 5-year comparison of hydroxyapatite-coated titanium plasma–sprayed and titanium plasma–sprayed cylinder dental implantsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1999
- Resorption of hydroxyapatite and fluorapatite coatings in manThe Journal of Bone and Joint Surgery. British volume, 1997
- Hydroxyapatite CoatingsClinical Orthopaedics and Related Research, 1988
- Plasma sprayed coatings of hydroxylapatiteJournal of Biomedical Materials Research, 1987
- Periodontal Disease in Pregnancy II. Correlation Between Oral Hygiene and Periodontal ConditionActa Odontologica Scandinavica, 1964