The effect of boundary constraints on finite element modelling of the human pelvis
- 1 March 2017
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 43 (1) , 48-57
Abstract
The use of finite element analysis (FEA) to investigate the biomechanics of anatomical systems critically relies on the specification of physiologically representative boundary conditions. The biomechanics of the pelvis has been the specific focus of a number of FEA studies previously, but it is also a key aspect in other investigations of, for example, the hip joint or new design of hip prostheses. In those studies, the pelvis has been modelled in a number of ways with a variety of boundary conditions, ranging from a model of the whole pelvic girdle including soft tissue attachments to a model of an isolated hemi-pelvis. The current study constructed a series of FEA models of the same human pelvis to investigate the sensitivity of the predicted stress distributions to the type of boundary conditions applied, in particular to represent the sacro-iliac joint and pubic symphysis. Varying the method of modelling the sacro-iliac joint did not produce significant variations in the stress distribution, however changes to the modelling of the pubic symphysis were observed to have a greater effect on the results. Over-constraint of the symphysis prevented the bending of the pelvis about the greater sciatic notch, and underestimated high stresses within the ilium. However, permitting medio-lateral translation to mimic widening of the pelvis addressed this problem. These findings underline the importance of applying the appropriate boundary conditions to FEA models, and provide guidance on suitable methods of constraining the pelvis when, for example, scan data has not captured the full pelvic girdle. The results also suggest a valid method for performing hemi-pelvic modelling of cadaveric or archaeological remains which are either damaged or incomplete.Keywords
This publication has 29 references indexed in Scilit:
- The influence of size, clearance, cartilage properties, thickness and hemiarthroplasty on the contact mechanics of the hip joint with biphasic layersJournal of Biomechanics, 2013
- Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trialsOrthopedic Reviews, 2013
- A finite element method approach to compare the wear of acetabular cups in polyethylene according to their lateral tilt in relation to the coronal planeWear, 2013
- The Effect of Boundary Condition on the Biomechanics of a Human Pelvic Joint Under an Axial Compressive Load: A Three-Dimensional Finite Element ModelJournal of Biomechanical Engineering, 2011
- Total Hip Arthroplasty – over 100 years of operative historyOrthopedic Reviews, 2011
- Computational assessment of the effect of polyethylene wear rate, mantle thickness, and porosity on the mechanical failure of the acetabular cement mantleJournal of Orthopaedic Research, 2009
- Problem of Stress Shielding and Improvement to the Hip Implant Designs: A ReviewJournal of Medical Sciences, 2007
- Three-Dimensional Finite Element Models of the Human Pubic Symphysis with Viscohyperelastic Soft TissuesAnnals of Biomedical Engineering, 2006
- Biomechanical study of load transfer of the pubic ramus due to pelvic inclination after hip joint surgery using a three-dimensional finite element modelJournal of Orthopaedic Science, 2004
- Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic BoneJournal of Biomechanical Engineering, 1995