Removal of a Broken Cannulated Tibial Nail
Authors:
- Gregory M. GeorgiadisGGGregory M. Georgiadis
- 1 April 2004
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 18 (4) , 247-249
Abstract
We present a case illustrating the extraction of a distal segment of a broken cannulated tibial nail. Using minimal soft tissue dissection, a ball-tipped guidewire is inserted through the medial malleolus. It is then threaded through the distal aspect of the broken nail. The guide wire is advanced further proximally out the standard knee incision. When the ball tip engages the end of the broken nail, it can be removed easily.Keywords
This publication has 13 references indexed in Scilit:
- Removal of the retained fragment of broken solid nails by the intra-medullary routeInjury, 2001
- Simple method for retrieval of distal segment of the broken interlocking intramedullary nailInjury, 1999
- Laparoscopic forceps removal of a broken tibial intramedullary nailInjury, 1998
- Removing a broken massive unreamed tibia nailDer Unfallchirurg, 1998
- Removal of a broken intramedullary tibial nail using a hand reamerInjury, 1997
- Recurrent Rotational Deformity Of The Femur After Static Locking Of Intramedullary Nails: Case ReportsThe Journal of Bone and Joint Surgery. British volume, 1997
- Removal of a broken solid intramedullary interlocking nail: A technical noteActa Orthopaedica, 1996
- Retrieval of a broken intramedullary femoral nailInjury, 1992
- Broken intramedullary nails.Journal of Bone and Joint Surgery, 1988
- Mechanical failure of intramedullary nails after fracture unionThe Journal of Bone and Joint Surgery. British volume, 1983