Analysis of Beams Prestressed with Unbonded Internal or External Tendons

Authors:

Abstract
The present study describes a nonlinear analysis model developed for the prediction of the complete moment versus deformation response of concrete beams containing bonded prestressing tendons, unbonded prestressing tendons (metallic or otherwise), and nonprestressed conventional reinforcing bars. The model uses an extensive iterative procedure for calculating the stress in unbonded tendons, fps, by performing a nonlinear analysis at various locations along the beam. The analysis is performed several times during any loading stage until the stress fps is calculated within a reasonable tolerance. Two important issues not addressed in previous investigations are considered in modeling the curvature distribution, namely: (1) The effects of member span‐to‐depth ratio and the level of shear force on the flexural deformations; and (2) the change in eccentricity under load (i.e., second‐order effects) for beams containing external tendons. Experimental verification was carried out using beam tests taken from 15 d...