Myocardial Lesion Size After Epicardial Electroporation Catheter Ablation After Subxiphoid Puncture
- 1 August 2014
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 7 (4) , 728-733
Abstract
Background—: Irreversible electroporation is a promising nonthermal ablation modality able to create deep myocardial lesions. We investigated lesion size after epicardial electroporation catheter ablation with various energy levels after subxiphoid pericardial puncture. Methods and Results—: In six 6-month-old pigs (60–75 kg), a custom deflectable octopolar 12-mm circular catheter with 2-mm ring electrodes was introduced via a deflectable sheath after pericardial access by subxiphoid puncture. Nonarcing, nonbarotraumatic, cathodal 50, 100, and 200 J electroporation applications were delivered randomly on the basal, mid and lateral left ventricle. After 3-month survival, myocardial lesion size and degree of intimal hyperplasia of the coronary arteries were analyzed histologically. Five animals survived the follow-up without complications and 1 animal died of shock after the subxiphoid puncture. At autopsy, whitish circular scars with indentation of the epicardium could be identified. Average lesion depths of the 50-, 100-, and 200-J lesions were 5.0±2.1, 7.0±2.0, and 11.9±1.5 mm, respectively. Average lesion widths of the 50-, 100-, and 200-J lesions were 16.6±1.1, 16.2±4.3, and 19.8±1.8 mm, respectively. In the 100- and 200-J cross sections, transmural left ventricular lesions and significant tissue shrinkage were observed. No intimal hyperplasia of the coronary arteries was observed. Conclusions—: Epicardial electroporation ablation after subxiphoid pericardial puncture can create deep, wide, and transmural ventricular myocardial lesions. There is a significant relationship between the amounts of electroporation energy delivered epicardially and lesion size in the absence of major adverse events.Keywords
This publication has 26 references indexed in Scilit:
- Minimal coronary artery damage by myocardial electroporation ablationEP Europace, 2012
- Feasibility of Electroporation for the Creation of Pulmonary Vein Ostial LesionsJournal of Cardiovascular Electrophysiology, 2011
- Atrial Coronary Arteries in Areas Involved in Atrial Fibrillation Catheter AblationCirculation: Arrhythmia and Electrophysiology, 2010
- Coronary Artery Injury Due to Catheter Ablation in AdultsCirculation, 2009
- Prevention of phrenic nerve injury during epicardial ablation: Comparison of methods for separating the phrenic nerve from the epicardial surfaceHeart Rhythm, 2009
- A Novel Nonthermal Energy Source for Surgical Epicardial Atrial Ablation: Irreversible ElectroporationThe Heart Surgery Forum, 2007
- Left phrenic nerve paresis complicating catheter radiofrequency ablation for Wolff-Parkinson-White syndromeAmerican Heart Journal, 1996
- Catheter Ablation Without Fulguration: Design and Performance of a New SystemPacing and Clinical Electrophysiology, 1989
- The Percutaneous Cardiac Mapping and Ablation Registry:* Final Summary of ResultsPacing and Clinical Electrophysiology, 1988
- Catheter Technique for Closed-Chest Ablation of the Atrioventricular Conduction SystemNew England Journal of Medicine, 1982