Moving reaction boundary and isoelectric focusing: IV. Systemic study on Hjertén's pH gradient mobilization
- 11 February 2009
- journal article
- electrodriven separation
- Published by Wiley in Journal of Separation Science
- Vol. 32 (4) , 585-596
Abstract
In this paper, Hjertén's mobilization of pH gradient in IEF was systemically and quantitatively analyzed with the Rr value of judgment expression comparing the fluxes of hydrogen and hydroxyl ions. The theoretical results show that (i) there is Rr = 0, viz., quasi‐equal fluxes of proton and hydroxyl ion, in a classic IEF with sulfuric acid and sodium hydroxide used as the anolyte and catholyte, respectively, this is the main reason why pH gradient is quite stable in IEF; (ii) but if the salt of sodium sulfate is added into the sodium hydroxide, there is Rr > 0, viz., the flux of proton being higher than that of hydroxyl ion, the Rr value implies a cathodic mobilization of pH gradient, and the higher the Rr value is the faster the cathodic mobilization becomes; (iii) if the salt is added into the sulfuric acid, there is Rr < 0, the Rr value indicates an anodic mobilization, and the smaller the Rr value is the faster the anodic mobilization turns. To test these theoretical results above, a novel procedure was developed for the run of classic IEF followed by Hjertén's mobilization of pH gradient. The strict experiments were in well coincidence with the theoretical results. The results have obvious significances for the mechanism and development of Hjertén's mobilization.Keywords
This publication has 51 references indexed in Scilit:
- Capillary isoelectric focusing of hemoglobin variants in the pediatric clinical laboratoryElectrophoresis, 1997
- Separation of human plasma/serum proteins by capillary isoelectric focusing in the absence of denaturing agentsElectrophoresis, 1997
- Capillary isoelectric focusing: A routine method for protein analysis?Electrophoresis, 1995
- Fluorescence‐labeled peptides as isoelectric point (pI) markers in capillary isoelectric focusing with fluorescence detectionElectrophoresis, 1995
- Fast analysis of proteins by isoelectric focusing performed in capillary array detected with concentration gradient imaging systemElectrophoresis, 1993
- Universal detection for capillary isoelectric focusing without mobilization using concentration gradient imaging systemAnalytical Chemistry, 1992
- INSTABILITY OF pH GRADIENTS FORMED BY ISOELECTRIC FOCUSING IN POLYACRYLAMIDE GELAnnals of the New York Academy of Sciences, 1973
- HISTORICAL AND THEORETICAL ASPECTS OF ISOELECTRIC FOCUSING*Annals of the New York Academy of Sciences, 1973
- Free zone electrophoresisChromatographic Reviews, 1967
- Isoelectric Fractionation, Analysis, and Characterization of Ampholytes in Natural pH Gradients. II. Buffering Capacity and Conductance of Isoionic Ampholytes.Acta Chemica Scandinavica, 1962