Apparent and reactive powers in three‐phase systems: In search of a physical meaning and a better resolution
Author:
- A. E. EmanuelAEA. E. Emanuel
- 1 January 1993
- journal article
- research article
- Published by Wiley in European Transactions on Electrical Power
- Vol. 3 (1) , 7-14
Abstract
This work analyzes the resolution of the apparent power in three‐phase systems defined by means of symmetrical components and using the product between an equivalent voltage [(V+)2+(V‐)2+(V0)2]1/2 and an equivalent current [(I+)2 + (I‐)2 + (I0)2]1/2. It was found that each component of such a defined apparent power S has a definite physical meaning. The results emphasize the need to separate the negative and zero sequence active power from the positive sequence power.Keywords
This publication has 4 references indexed in Scilit:
- Powers in nonsinusoidal situations-a review of definitions and physical meaningIEEE Transactions on Power Delivery, 1990
- Orthogonal decomposition of the currents in a 3-phase nonlinear asymmetrical circuit with a nonsinusoidal voltage sourceIEEE Transactions on Instrumentation and Measurement, 1988
- Reactive Power Concepts in Need of ClarificationTransactions of the American Institute of Electrical Engineers, 1933
- Power Factor in Polyphase CircuitsTransactions of the American Institute of Electrical Engineers, 1920