Monitoring PM2.5 at a Large Shopping Mall: A Case Study in Macao
Open Access
Abstract
Employees work long hours in an environment where the ambient air quality is poor, directly affecting their work efficiency. The concentration of particulate matters (PM) produced by the interior renovation of shopping malls has not received particular attention in Macao. Therefore, this study will investigate the indoor air quality (IAQ), in particular of PM2.5, in large-scale shopping mall renovation projects. This study collected on-site PM data with low-cost portable monitoring equipment placed temporarily at specific locations to examine whether the current control measures are appropriate and propose some improvements. Prior to this study, there were no measures being implemented, and on-site monitoring to assess the levels of PM2.5 concentrations was non-existent. The results show the highest level of PM2.5 recorded in this study was 559.00 μg/m3. Moreover, this study may provide a reference for decision-makers, management, construction teams, design consultant teams, and renovation teams of large-scale projects. In addition, the monitoring of IAQ can ensure a comfortable environment for employees and customers. This study concluded that the levels of PM2.5 concentration have no correlation with the number of on-site workers, but rather were largely influenced by the processes being performed on-site.Keywords
This publication has 19 references indexed in Scilit:
- Exposure of particulate matter 2.5 (PM2.5) on lung function performance of construction workersAIP Conference Proceedings, 2019
- Indoor air quality at shopping malls in Kota Kinabalu, Sabah (particulate matter and ozone)Annals of Tropical Medicine and Public Health, 2017
- Impact of indoor environmental quality on occupant well-being and comfort: A review of the literatureInternational Journal of Sustainable Built Environment, 2016
- Role of mechanical ventilation in the airborne transmission of infectious agents in buildingsIndoor Air, 2015
- The relation between past exposure to fine particulate air pollution and prevalent anxiety: observational cohort studyBMJ, 2015
- Human Occupancy as a Source of Indoor Airborne BacteriaPLOS ONE, 2012
- Measurement of Ultrafine Particles and Other Air Pollutants Emitted by Cooking ActivitiesInternational Journal of Environmental Research and Public Health, 2010
- Determining indoor air quality and identifying the origin of odour episodes in indoor environmentsJournal of Environmental Sciences, 2009
- The sick building syndromeIndian Journal of Occupational and Environmental Medicine, 2008
- Indoor Air Quality: A Psychosocial PerspectiveJournal of Occupational and Environmental Medicine, 1990