Documentation of Skin-Related Issues Associated with Continuous Glucose Monitoring Use in the Scientific Literature
Authors:
- 1 October 2019
- journal article
- research article
- Published by SAGE Publications in Diabetes Technology & Therapeutics
- Vol. 21 (10) , 538-545
Abstract
The average wear time of CGM systems steadily increased over the last years. Increased wear times are likely achieved by using adhesives with a longer adherence time, which may have a more pronounced effect on the skin than adhesives with shorter adherence time. In this project, a structured literature search was performed to assess how potential skin-related issues with CGM usage have been reported in scientific literature in the last 5 years. The literature search was performed with four search terms in the PubMed database. In sum, 279 articles were analyzed. Skin-related issues were mentioned in 19.0% of articles (53 out of 279). With respect to articles mentioning skin-related issues, CGM performance or efficacy was the study’s main topic of most of these studies, whereas the minority used CGM as “add-on” to assess other objectives. There was a varying degree in how detailed skin-related issues were described and no uniform structured documentation was given. Whereas some articles only described findings, other already documented final diagnoses, such as contact dermatitis. Furthermore, inconsistent wordings for comparable issues were used. The most frequent issues were pain, itching, erythema, bleeding, bruising and allergic reactions. To draw possible conclusions about the occurrence of skin-related issues during CGM use, more reports about skin-related issues in scientific literature are needed. A more detailed and uniformly structured documentation, possibly facilitated by a generally accepted guideline for structured descriptions, of skin-related issues could be helpful to enable clear differentiations between the described skin reactions.Keywords
This publication has 29 references indexed in Scilit:
- Allergic contact dermatitis caused by medical devices for diabetes patients: A reviewContact Dermatitis, 2018
- Preserving Skin Integrity with Chronic Device Use in DiabetesDiabetes Technology & Therapeutics, 2018
- Further Evidence of Severe Allergic Contact Dermatitis From Isobornyl Acrylate While Using a Continuous Glucose Monitoring SystemJournal of Diabetes Science and Technology, 2018
- Continuous glucose monitoring: A review of the technology and clinical useDiabetes Research and Clinical Practice, 2017
- Manufacturing Process Changes and Reduced Skin Irritations of an Adhesive Patch Used for Continuous Glucose Monitoring DevicesJournal of Diabetes Science and Technology, 2017
- Allergic contact dermatitis caused by isobornyl acrylate in Freestyle® Libre, a newly introduced glucose sensorContact Dermatitis, 2017
- Adhesives Used for Diabetes Medical DevicesJournal of Diabetes Science and Technology, 2016
- The Artificial Pancreas in 2016: A Digital Treatment Ecosystem for DiabetesDiabetes Care, 2016
- Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient dataBMJ, 2011
- OCCURENCE OF ADVERSE EVENTS DUE TO CONTINUOUS GLUCOSE MONITORINGBiomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia, 2007