Minimizing the perfusion system by integration of the components. Does it affect the hematocrit drop and transfused red blood cells? A retrospective audit
- 3 June 2014
- journal article
- research article
- Published by SAGE Publications in Perfusion
- Vol. 30 (2) , 127-131
Abstract
Background: We evaluate the affect on the hematocrit (Hct) drop and the amount of transfused red blood cells (RBCs) during cardiopulmonary bypass (CPB) in adult cardiac surgery patients due to minimizing the CPB circuit by using integrated components. Methods: Two hundred and seventy-two patients were included in this retrospective audit. Patients were assigned to three cohorts: the first cohort consisted of patients operated on with a CPB circuit volume of 1630 ml in 2008; the second cohort of such patients in 2010, with 1380 ml; and the third cohort of such patients in 2011, with 1250 ml. Results: There were no significant differences with respect to patient demographics. The priming volume was consecutively significantly reduced; (1635 ± 84 ml, 1384 ± 72 ml and 1256 ± 130 ml, p<0.0001). A trend of decreased amount of RBCs during CPB was visible (cohort 1630: 98 ± 195 ml, cohort 1380: 35 ± 151 ml and cohort 1250: 48 ± 113 ml, p=0.02). Also, the amount of RBCs during the total CPB procedure shows a decreased trend (cohort 1630: 122 ± 230 ml, cohort 1380: 52 ± 180 ml and cohort 1250: 71 ± 156 ml, p=0.04). Blood loss during CPB was significantly lower in cohorts 1380 and 1250 (1630: 922 ± 378 ml, 1380: 706 ± 347 ml and 1250: 708 ± 418 ml, p<0.0001). The volume of diuresis was significantly larger in cohort 1630 (1630: 1166 ± 800 ml, 1380: 477 ± 530 ml and 1250: 523 ± 504 ml, p<0.0001). The Hct drop at the start and end of CPB was significantly reduced comparing cohort 1630 with cohort 1250 (1630: 32 ± 7%, 1380: 30 ± 7% and 1250: 28 ± 10%, p=0.002) at the start of CPB and (1630: 31 ± 7%, 1380: 29 ± 7% and 1250: 28 ± 8%, p=0.016) at the end of CPB. The Hct values at the start and end of CPB were significantly different between the cohorts (1680: 0.23 ± 0.03 L/L - 0.22 ± 0.02 L/L, 1380: 0.25 ± 0.03 L/L - 0.25 ± 0.03 L/L and 1250: 0.25 ± 0.03 L/L- 0.25 ± 0.03 L/L, p= 0.001 and 0.0001). Conclusions: Minimizing our CPB circuit by using integrated components has affected the drop of Hct and the amount of transfused RBCs.Keywords
This publication has 14 references indexed in Scilit:
- The effect of retrograde autologous priming on intraoperative blood product transfusion in coronary artery bypass graftingPerfusion, 2013
- Blood Transfusion and Infection After Cardiac SurgeryThe Annals of Thoracic Surgery, 2013
- The effect of retrograde autologous priming volume on haemodilution and transfusion requirements during cardiac surgeryInteractive CardioVascular and Thoracic Surgery, 2013
- The Aachen MiniHLM—A Miniaturized Heart‐Lung Machine for Neonates With an Integrated Rotary Blood PumpArtificial Organs, 2010
- Hematocrit on Cardiopulmonary Bypass and Outcome After Coronary Surgery in Nontransfused PatientsThe Annals of Thoracic Surgery, 2010
- Perfusion Approaches to Blood ConservationSeminars in Cardiothoracic and Vascular Anesthesia, 2007
- Extracorporeal Circulation, Optimized: A Pilot StudyArtificial Organs, 2007
- Intraoperative Red Blood Cell Transfusion During Coronary Artery Bypass Graft Surgery Increases the Risk of Postoperative Low-Output Heart FailureCirculation, 2006
- Low Hematocrit During Cardiopulmonary Bypass is Associated With Increased Risk of Perioperative Stroke in Cardiac SurgeryThe Annals of Thoracic Surgery, 2005
- Hemodilution during cardiopulmonary bypass is an independent risk factor for acute renal failure in adult cardiac surgeryThe Journal of Thoracic and Cardiovascular Surgery, 2005