An FBG-Based Sensing Glove to Measure Dynamic Finger Flexure With an Angular Resolution of 0.1$^{\circ }$ up to Speeds of 80$\mathrm{^{\circ }\text{/s}}$
- 28 May 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 37 (18) , 4734-4740
Abstract
We demonstrate a fiber Bragg grating (FBG) sensor-based highly accurate instrumented glove that can measure finger flexure with an angular resolution of 0.1°. The sensing unit consists of an FBG that is very sensitive to axial strain induced by the flexing of fingers. The spectral shift of the reflection spectrum of the FBG varies linearly with the joint rotation angle. The sensor offers a very high angular resolution of 0.1° with a very high sensitivity of 18.45 pm/degree. The accuracy evaluated using a mechanical setup and the human hand is 0.13° and 0.67° respectively. This is much better than many other reported sensors. The sensor showed excellent repeatability with a maximum standard deviation of 0.30° and 0.79° on a mechanical setup and the human hand respectively. The results are validated using a pre-calibrated inertial measurement unit (IMU) sensor. The sensor also exhibited much better dynamic response compared to the IMU up to a rotation speed of 80°/s. These results demonstrate that our sensor is a strong potential candidate for the development of high-accuracy instrumented gloves that could be used to monitor the progress in the rehabilitation of stroke survivors. This work focuses on the careful characterization of the sensor to establish it as a sensitive and practical approach. The accuracy, repeatability and dynamic response were evaluated using a motorized mechanical model of a finger joint and also on the hands of two human subjects.Keywords
Funding Information
- Indian Institute of Technology, Gandhinagar and Visvesveraya Ph.D. Fellowship Scheme, Ministry of Electronics & Information Technology(MeitY), Government of India
This publication has 31 references indexed in Scilit:
- A novel array of flex sensors for a goniometric gloveSensors and Actuators A: Physical, 2014
- Effects of substituting anthropometric joints with revolute joints in humanoid robots and robotic hands: a case studyRobotica, 2013
- Multi-finger coordination in healthy subjects and stroke patients: a mathematical modelling approachJournal of NeuroEngineering and Rehabilitation, 2011
- Development and evaluation of a low-cost sensor glove for assessment of human finger movements in neurophysiological settingsJournal of Neuroscience Methods, 2009
- Simultaneous measurement of strain and temperature using single tilted fibre Bragg gratingElectronics Letters, 2008
- Development of a Data Glove With Reducing Sensors Based on Magnetic InductionIEEE Transactions on Industrial Electronics, 2005
- A strain gauge tactile sensor for finger-mounted applicationsIEEE Transactions on Instrumentation and Measurement, 2002
- Simultaneous strain, temperature and vibration measurementusing amultiplexed in-fibre-Bragg-grating/fibre-Fabry-Perot sensor systemElectronics Letters, 1997
- Model-based analysis of hand postureIEEE Computer Graphics and Applications, 1995
- Evaluation of a fiber optic glove for semi-automated goniometric measurementsJournal of Rehabilitation Research and Development, 1990