Impact of simple electrocardiographic markers as predictors for deterioration of left ventricular function in patients with frequent right ventricular apical pacing
Authors:
- 26 September 2017
- journal article
- research article
- Published by Springer Nature in Heart and Vessels
- Vol. 33 (3) , 299-308
Abstract
Several trials demonstrated that frequent right ventricular apical pacing (RVAP) was associated with cardiac dysfunction and an increased rate of heart failure hospitalization. However, there are few reports about the 12-lead electrocardiogram (12-ECG) parameters at the time of device implantation to predict deterioration of LVEF in patients with frequent RVAP. We retrospectively studied 115 consecutive patients undergoing pacemaker or implantable cardioverter-defibrillator implantation with RVAP, with rate of ventricular pacing ≥ 40% and LVEF ≥ 50% at the time of implantation. We compared the 12-ECG characteristics at the time of device implantation between patients with deterioration of LVEF (≥ 10% reduction) and those without. Twenty-nine patients (25%) had deteriorated LVEF with a decrease in mean LVEF from 59 to 40% during a median follow-up period of 8.9 [4.6–13.7] years. Multivariate logistic regression analysis showed that cumulative % of ventricular pacing [odds ratio (OR) 1.04 per 1% increase, 95% confidence interval (CI) 1.01–1.09, p = 0.04], notching of baseline paced QRS in limb leads (OR 5.04, 95% CI 1.59–19.6, p = 0.005) and the QS pattern in all precordial leads (OR 3.56, 95% CI 1.21–10.8, p = 0.02) were independently associated with deterioration of LVEF. The QS pattern of baseline paced QRS in all precordial leads had 58% sensitivity, 93% specificity for the RV lead position at the tip of RV apex. In conclusion, considering OR by multivariate analysis, notching of baseline paced QRS in limb leads and the QS pattern in all precordial leads at device implantation may be simple and useful predictors to identify patients who are at risk for deterioration of cardiac function during long-term RVAP. 12-ECG monitoring at device implantation and avoidance of the RVAP site showing a QS pattern may be important to prevent deterioration of cardiac function in patients with frequent RVAP.Keywords
This publication has 16 references indexed in Scilit:
- Validation of Conventional Fluoroscopic and ECG Criteria for Right Ventricular Pacemaker Lead Position Using Cardiac Computed TomographyPacing and Clinical Electrophysiology, 2013
- Assessment of optimal right ventricular pacing site using invasive measurement of left ventricular systolic and diastolic functionEP Europace, 2013
- Paced QRS Duration as a Predictor for Clinical Heart Failure Events During Right Ventricular Apical Pacing in Patients with Idiopathic Complete Atrioventricular Block: Results from an Observational Cohort Study (PREDICT-HF)European Journal of Heart Failure, 2013
- Impact of temporary right ventricular pacing from different sites on echocardiographic indices of cardiac functionEP Europace, 2011
- Fragmented Wide QRS on a 12-Lead ECGCirculation: Arrhythmia and Electrophysiology, 2008
- Heart Failure During Cardiac PacingCirculation, 2006
- Prolonged Paced QRS Duration as a Predictor for Congestive Heart Failure in Patients with Right Ventricular Apical PacingPacing and Clinical Electrophysiology, 2005
- Heart failure hospitalization is more common in pacemaker patients with sinus node dysfunction and a prolonged paced QRS durationHeart Rhythm, 2005
- Adverse Effect of Ventricular Pacing on Heart Failure and Atrial Fibrillation Among Patients With Normal Baseline QRS Duration in a Clinical Trial of Pacemaker Therapy for Sinus Node DysfunctionCirculation, 2003
- Dual-Chamber Pacing or Ventricular Backup Pacing in Patients With an Implantable DefibrillatorJAMA, 2002