Pulsed Acceleration Charge Detection Mass Spectrometry: Application to Weighing Electrosprayed Droplets
Authors:
- 11 October 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (22) , 8431-8439
Abstract
We describe a new approach to measuring the masses of individual macroions. The method employs a pulsed acceleration tube located between two sensitive image charge detectors. The charge and velocity of the macroion are recorded with the first image charge detector. The ion is pulse accelerated through a known voltage drop, and then the charge and velocity are remeasured using the second image charge detector. The mass of the ion is deduced from its charge and its initial and final velocities. The approach has been used to measure masses in the 1010−1014 Da range with z = 103−106 and m/z = 106−109. It should be extendable to masses of 6 Da. We have used the method to determine the size and charge of water droplets transmitted through a capillary interface and an aperture interface. The droplets detected from the aperture interface are ∼1 order of magnitude smaller in mass than those detected from the capillary interface. The droplets from both interfaces have relatively low charges, particularly with the capillary interface where they are only charged to a small fraction of the Rayleigh limit. These results suggest that the aerodynamic breakup of the droplets plays a significant role in the mechanism of electrospray ionization.Keywords
This publication has 27 references indexed in Scilit:
- Analysis of Megadalton Ions Using Cryodetection MALDI Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2005
- Comparative ESI-MS study of ∼2.2 MDa native hemocyanins from deep-sea and shore crabs: from protein oligomeric state to biotopeJournal of the American Society for Mass Spectrometry, 2003
- Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometryMass Spectrometry Reviews, 1999
- Detection of the Intact GroEL Chaperonin Assembly by Mass SpectrometryJournal of the American Chemical Society, 1999
- Disassembly of intact multiprotein complexes in the gas phaseCurrent Opinion in Structural Biology, 1999
- Mass spectrometry of ribosomes and ribosomal subunitsProceedings of the National Academy of Sciences, 1998
- Trapping, Detection, and Mass Measurement of Individual Ions in a Fourier Transform Ion Cyclotron Resonance Mass SpectrometerJournal of the American Chemical Society, 1994
- Trapping, detection and reaction of very large single molecular ions by mass spectrometryNature, 1994
- Ultra-high velocity impacts: cratering studies of microscopic impacts from 3 km/s to 30 km/sInternational Journal of Impact Engineering, 1993
- A hypervelocity - microparticle - impacts laboratory with 100-km/s projectilesInternational Journal of Impact Engineering, 1990