The accuracy of sizing of the femoral component in total knee replacement
- 26 June 2012
- journal article
- research article
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (10) , 2309-2313
Abstract
Purpose: Femoral sizing in total knee replacement is important. Either undersizing or oversizing may result in deleterious effects to the clinical outcome after the surgery. There has been no study on the precision and accuracy of femoral sizing and the effect of measurement at different landmarks over the distal femur. This study assesses the intra‐observer and inter‐observer error of femoral sizing and identifies the effect of the placement site of the anterior referencing tool on femoral sizing.Methods: Five investigators with different clinical experience measured the femoral size of 10 cadaveric specimens twice using three anterior referencing tool. The measurement of the femoral size was repeated at nine designated points on the anterior cortex of the cadaveric femora.Results: Excellent intraobserver and interobserver agreements were obtained using the three anterior referencing tools. When the size on which the majority agreed was regarded as the actual size of the specimen, measurement at the nine designated points on the anterior cortex showed a deviation from the actual size from 6.2 to 46.2 %. Placing the femoral sizer stylus at the middle and 2 cm above the proximal margin of the anterior femoral condyle yielded the highest precision and accuracy.Conclusion: Regardless of the experience of the surgeons, measurement of the femoral size using the three anterior referencing tools is very accurate. Placing the stylus of the femoral sizer at the middle and 2 cm above the proximal margin of the anterior femoral condyle best reflects the actual size of the femur.Level of evidence: Experimental study.Keywords
This publication has 12 references indexed in Scilit:
- The Dangers of Stopping a Trial Too EarlyJournal of Bone and Joint Surgery, 2012
- Upsizing the femoral component increases patellofemoral contact force in total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2012
- Intraoperative Morphometric Study of Gender Differences in Asian FemursThe Journal of Arthroplasty, 2011
- Gender differences in the knees of Chinese populationKnee Surgery, Sports Traumatology, Arthroscopy, 2010
- Sagittal bowing of the distal femur in Chinese patients who require total knee arthroplastyJournal of Orthopaedic Research, 2005
- Femoral component sizing in total knee arthroplasty: Size matched resection versus flexion space balancingThe Journal of Arthroplasty, 2004
- Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems.2003
- The influence of femoral rollback on patellofemoral contact loads in total knee arthroplastyThe Journal of Arthroplasty, 2001
- Component size asymmetry in bilateral total knee arthroplasty.2001
- Flexion Instability After Primary Posterior Cruciate Retaining Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998