Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy
Authors:
Open Access
- 15 October 2020
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (11) , 124-131
Abstract
Purpose: The objective of this study was to evaluate the impact of the magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and range in pencil beam scanning proton therapy.Methods: “Field regulation” — a feature to reduce the switching time between layers by applying a magnetic field setpoint (instead of a current setpoint) has been implemented on the proton beam delivery system at the Miami Cancer Institute. To investigate the impact of field regulation for the volumetric repainting technique, several spot maps were generated with beam delivery sequence in both directions, that is, irradiating from the deepest layer to the most proximal layer (“down” direction) as well as irradiating from the most proximal layer to the deepest layer (“up” direction). Range measurements were performed using a multi‐layer ionization chamber array. Spot positions were measured using two‐dimensional and three‐dimensional scintillation detectors. For range and central‐axis spot position, spot maps were delivered for energies ranging from 70–225 MeV. For off‐axis spot positions, the maps were delivered for high‐, medium, and low‐energies at eight different gantry angles. The results were then compared between the “up” and “down” directions.Results: The average difference in range for given energy between “up” and “down” directions was 0.0 ± 0.1 mm. The off‐axis spot position results showed that 846/864 of the spots were within ±1 mm, and all off‐axis spot positions were within ±1.2 mm. For spots (n = 126) at the isocenter, the evaluation between “up” and “down” directions for given energy showed the spot position difference within ±0.25 mm. At the nozzle entrance, the average differences in X and Y positions for given energy were 0.0 ± 0.2 mm and −0.0 ± 0.4 mm, respectively. At the nozzle exit, the average differences in X and Y positions for given energy were 0.0 ± 0.1 mm and −0.1 ± 0.1 mm, respectively.Conclusion: The volumetric repainting technique in magnetic field regulation mode resulted in acceptable spot position and range differences for our beam delivery system. The range differences were found to be within ±1 mm (TG224). For the spot positions (TG224: ±1 mm), the central axis measurements were within ±1 mm, whereas for the off‐axis measurements, 97.9% of the spots were within ±1 mm, and all spots were within ±1.2 mm.Keywords
This publication has 22 references indexed in Scilit:
- Particle therapy of moving targets—the strategies for tumour motion monitoring and moving targets irradiationBritish Journal of Radiology, 2016
- Beam Delivery Method for Carbon-ion Radiotherapy with the Heavy-ion Medical Accelerator in ChibaInternational Journal of Particle Therapy, 2016
- Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzlesPhysics in Medicine & Biology, 2013
- Pencil beam characteristics of the next-generation proton scanning gantry of PSI: design issues and initial commissioning resultsThe European Physical Journal Plus, 2011
- Motion in radiotherapy: particle therapyPhysics in Medicine & Biology, 2011
- A study on repainting strategies for treating moderately moving targets with proton pencil beam scanning at the new Gantry 2 at PSIPhysics in Medicine & Biology, 2010
- Breathing interplay effects during proton beam scanning: simulation and statistical analysisPhysics in Medicine & Biology, 2009
- Quantification of interplay effects of scanned particle beams and moving targetsPhysics in Medicine & Biology, 2008
- A novel gantry for proton therapy at the Paul Scherrer InstituteAIP Conference Proceedings, 2001
- Effects of respiratory motion on dose uniformity with a charged particle scanning methodPhysics in Medicine & Biology, 1992