Multi-modal myocontrol: Testing combined force- and electromyography
Authors:
- 1 July 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2017, 1364-1368
Abstract
Myocontrol, that is control of prostheses using bodily signals, has proved in the decades to be a surprisingly hard problem for the scientific community of assistive and rehabilitation robotics. In particular, traditional surface electromyography (sEMG) seems to be no longer enough to guarantee dexterity (i.e., control over several degrees of freedom) and, most importantly, reliability. Multi-modal myocontrol is concerned with the idea of using novel signal gathering techniques as a replacement of, or alongside, sEMG, to provide high-density and diverse signals to improve dexterity and make the control more reliable. In this paper we present an offline and online assessment of multi-modal sEMG and force myography (FMG) targeted at hand and wrist myocontrol. A total number of twenty sEMG and FMG sensors were used simultaneously, in several combined configurations, to predict opening/closing of the hand and activation of two degrees of freedom of the wrist of ten intact subjects. The analysis was targeted at determining the optimal sensor combination and control parameters; the experimental results indicate that sEMG sensors alone perform worst, yielding a nRMSE of 9.1%, while mixing FMG and sEMG or using FMG only reduces the nRMSE to 5.2 - 6.6%. To validate these results, we engaged the subject with median performance in an online goal-reaching task. Analysis of this further experiment reveals that the online behaviour is similar to the offline one.Keywords
This publication has 13 references indexed in Scilit:
- Literature Review on Needs of Upper Limb Prosthesis UsersFrontiers in Neuroscience, 2016
- Force Myography to Control Robotic Upper Extremity Prostheses: A Feasibility StudyFrontiers in Bioengineering and Biotechnology, 2016
- Multi-Modal Sensing Techniques for Interfacing Hand Prostheses: A ReviewIEEE Sensors Journal, 2015
- Surveying the interest of individuals with upper limb loss in novel prosthetic control techniquesJournal of NeuroEngineering and Rehabilitation, 2015
- Non-invasive control interfaces for intention detection in active movement-assistive devicesJournal of NeuroEngineering and Rehabilitation, 2014
- A Comparative Analysis of Three Non-Invasive Human-Machine Interfaces for the DisabledFrontiers in Neurorobotics, 2014
- Stable myoelectric control of a hand prosthesis using non-linear incremental learningFrontiers in Neurorobotics, 2014
- Control of Upper Limb Prostheses: Terminology and Proportional Myoelectric Control—A ReviewIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2012
- Surface muscle pressure as a measure of active and passive behavior of muscles during gaitMedical Engineering & Physics, 2010
- Residual kinetic imaging: a versatile interface for prosthetic controlRobotica, 2005