IMPROD biparametric MRI in men with a clinical suspicion of prostate cancer (IMPROD Trial): Sensitivity for prostate cancer detection in correlation with whole‐mount prostatectomy sections and implications for focal therapy
- 22 March 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (5) , 1641-1650
Abstract
Background: Prostate MRI is increasingly being used in men with a clinical suspicion of prostate cancer (PCa). However, development and validation of methods for focal therapy planning are still lagging.Purpose: To evaluate the diagnostic accuracy on lesion, region‐of‐interest (ROI), and voxel level of IMPROD biparametric prostate MRI (bpMRI) for PCa detection in men with a clinical suspicion of PCa who subsequently underwent radical prostatectomy.Study Type: Prospective single‐institution clinical trial (NCT01864135).Population: Sixty‐four men who underwent radical prostatectomy after IMPROD bpMRI performed in prebiopsy settings.Field Strength/Sequence: IMPROD bpMRI consisted of T2‐weighted imaging (T2w) and three separate diffusion‐weighted imaging acquisitions with an average acquisition time of 15 minutes.Assessment: The diagnostic accuracy of prospectively reported manual cancer delineations and regions increased with 3D dilation were evaluated on the voxel level (volume of 1.17 mm3, 1 mm3, 125 mm3) as well as the 36 ROI level. Only PCa lesions with a diameter ≥ 5 mm or any Gleason Grade 4 were analyzed. All data and protocols are freely available at: http://petiv.utu.fi/improdStatistical Tests: Sensitivity, specificity, accuracy.Results: In total, 99 PCa lesions were identified. Forty (40%, 40/99) had a Gleason score (GS) of >3 + 4. Twenty‐eight PCa lesions (28%, 28/99) were missed by IMPROD bpMRI, three (7.5%, 3/40) with GS >3 + 4. 3D dilation of manual cancer delineations in all directions by ~10–12 mm (corresponding to the Hausdorff distance) was needed to achieve sensitivity approaching 100% on a voxel level.Data Conclusion: IMPROD bpMRI had a high sensitivity on lesion level for PCa with GS >3 + 4. Increasing 3D lesion delineations by ~10–12 mm (corresponding to the Hausdorff distance) was needed to achieve high sensitivity on the voxel level. Such information may help in planning ablation therapies.Level of Evidence: 1Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;50:1641–1650.Keywords
Funding Information
- Suomen Kulttuurirahasto
- Sigrid Juséliuksen Säätiö
This publication has 28 references indexed in Scilit:
- Prebiopsy multiparametric 3T prostate MRI in patients with elevated PSA, normal digital rectal examination, and no previous biopsyJournal of Magnetic Resonance Imaging, 2014
- Prostate tumour volumes: evaluation of the agreement between magnetic resonance imaging and histology using novel co‐registration softwareBJU International, 2014
- Standards of Reporting for MRI-targeted Biopsy Studies (START) of the Prostate: Recommendations from an International Working GroupEuropean Urology, 2013
- Reply to Letter to the Editor re: ESUR prostate MR guidelinesEuropean Radiology, 2013
- Challenges in accurate registration of 3-D medical imaging and histopathology in primary prostate cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2013
- Improved detection of localized prostate cancer using co-registered MRI and 11C-acetate PET/CTEuropean Journal of Radiology, 2012
- Introducing Parametric Fusion PET/MRI of Primary Prostate CancerJournal of Nuclear Medicine, 2012
- Transatlantic Consensus Group on active surveillance and focal therapy for prostate cancerBJU International, 2011
- Multiparametric 3T Prostate Magnetic Resonance Imaging to Detect Cancer: Histopathological Correlation Using Prostatectomy Specimens Processed in Customized Magnetic Resonance Imaging Based MoldsJournal of Urology, 2011
- Multiparametric magnetic resonance imaging for the detection and localization of prostate cancer: combination of T2‐weighted, dynamic contrast‐enhanced and diffusion‐weighted imagingBJU International, 2010