Towards Steering a High-Dose Rate Brachytherapy Needle With a Robotic Steerable Stylet
- 18 January 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (1) , 54-65
Abstract
Steerable needles are desired for many applications within the medical field. One such application is high-dose rate (HDR) brachytherapy. In this paper, an adaptive control system is proposed to provide control of the planar bending angle or deflection distance of a tendon-driven continuum joint, which can be inserted as the stylet in a commercial hollow needle for HDR brachytherapy. Proportional–integral–derivative (PID) controllers are a common method of control. However, significant tuning may be required to achieve the desired dynamic response, and the tuned gains may not achieve the desired response in a different environment or if the system model varies. Steerable needles must navigate through tissues of differing viscoelastic properties and the use of nitinol for the joint and tendons of a steerable needle leads to change in the system parameters due to change in the phase of the nitinol material. In this article, we propose the real-time adaptation of PID gains using model reference adaptive control techniques to control the planar bending angle or deflection distance of a steerable stylet and needle system.Keywords
Funding Information
- National Science Foundation Graduate Research Fellowship Program (DGE-2039655)
This publication has 49 references indexed in Scilit:
- What is the nature of pancreatic consistency? Assessment of the elastic modulus of the pancreas and comparison with tactile sensation, histology, and occurrence of postoperative pancreatic fistula after pancreaticoduodenectomySurgery, 2014
- AAPM and GEC‐ESTRO guidelines for image‐guided robotic brachytherapy: Report of Task Group 192Medical Physics, 2014
- Experimental and numerical analysis of soft tissue stiffness measurement using manual indentation device – significance of indentation geometry and soft tissue thicknessSkin Research and Technology, 2013
- A Flexure-Based Steerable Needle: High Curvature With Reduced Tissue DamageIEEE Transactions on Biomedical Engineering, 2012
- A novel curvilinear approach for prostate seed implantationMedical Physics, 2012
- American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) Practice Guideline for the Performance of High-Dose-Rate BrachytherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- LQG-Based Planning, Sensing, and Control of Steerable Needles2010
- Dosimetric equivalence of nonstandard HDR brachytherapy catheter patternsMedical Physics, 2008
- Measurement of prostate rotation during insertion of needles for brachytherapyRadiotherapy and Oncology, 2005
- Collagen‐immobilized poly (vinyl alcohol) as an artificial cornea scaffold that supports a stratified corneal epitheliumJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005