The Use of Joint Time Frequency Analysis to Quantify the Effect of Ventilation on the Pulse Oximeter Waveform
- 1 June 2006
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 20 (2) , 81-87
Abstract
Objective. In the process of determining oxygen saturation, the pulse oximeter functions as a photoelectric plethysmograph. By analyzing how the frequency spectrum of the pulse oximeter waveform changes over time, new clinically relevant features can be extracted. Methods. Thirty patients undergoing general anesthesia for abdominal surgery had their pulse oximeter, airway pressure and CO2 waveforms collected (50 Hz). The pulse oximeter waveform was analyzed with a short-time Fourier transform using a moving 4096 point Hann window of 82 seconds duration. The frequency signal created by positive pressure ventilation was extracted using a peak detection algorithm in the frequency range of ventilation (0.08–0.4 Hz = 5–24 breaths/minute). The respiratory rate derived in this manner was compared to the respiratory rate as determined by CO2 detection. Results. In total, 52 hours of telemetry data were analyzed. The respiratory rate measured from the pulse oximeter waveform was found to have a 0.89 linear correlation when compared to CO2 detection and airway pressure change. the bias was 0.03 breath/min, SD was 0.557 breath/min and the upper and lower limits of agreement were 1.145 and −1.083 breath/min respectively. The presence of motion artifact proved to be the primary cause of failure of this technique. Conclusion. Joint time frequency analysis of the pulse oximeter waveform can be used to determine the respiratory rate of ventilated patients and to quantify the impact of ventilation on the waveform. In addition, when applied to the pulse oximeter waveform new clinically relevant features were observed.Keywords
This publication has 14 references indexed in Scilit:
- The Effect of Venous Pulsation on the Forehead Pulse Oximeter Wave Form as a Possible Source of Error in Spo2 CalculationAnesthesia & Analgesia, 2005
- An Algorithm for the Detection of Individual Breaths from the Pulse Oximeter WaveformJournal of Clinical Monitoring and Computing, 2004
- Neural network for photoplethysmographic respiratory rate monitoringMedical & Biological Engineering & Computing, 2003
- Monitoring of respiratory rate in postoperative care using a new photoplethysmographic techniqueJournal of Clinical Monitoring and Computing, 2000
- Pulse oximetry plethysmographic waveform during changes in blood volumeBritish Journal of Anaesthesia, 1999
- Monitoring of heart and respiratory rates by photoplethysmography using a digital filtering techniqueMedical Engineering & Physics, 1996
- Signal processing methods for pulse oximetryComputers in Biology and Medicine, 1996
- The detection of peripheral venous pulsation using the pulse oximeter as a plethysmographJournal of Clinical Monitoring and Computing, 1993
- A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurementComputers in Biology and Medicine, 1990
- PHOTO-ELECTRIC PLETHYSMOGRAPHY AS A MONITORING DEVICE IN ANAESTHESIABritish Journal of Anaesthesia, 1985