Factors Associated with Incomplete Insertion of Electrodes in Cochlear Implant Surgery: A Histopathologic Study
Open Access
- 19 June 2010
- journal article
- research article
- Published by S. Karger AG in Audiology and Neurotology
- Vol. 16 (2) , 69-81
Abstract
Objectives: Atraumatic and complete insertion of the electrode array is a stated objective of cochlear implant surgery. However, it is known that obstructions within the cochlea such as new bone formation, cochlear otosclerosis, temporal bone fracture, and cochlear anomalies may limit the depth of insertion of the electrode array. In addition, even among patients without obvious clinical or radiographic indicators of obstruction, incomplete insertion may occur. The current study is a histopathologic evaluation of possible sources of resistance to insertion of the electrode array using the temporal bone collection of the Massachusetts Eye and Ear Infirmary. Methods: Forty temporal bones from patients who in life had undergone cochlear implantation were evaluated. Temporal bones were removed at autopsy and fixed and prepared for histologic study by standard techniques. Specimens were then serially sectioned and reconstructed by 2-dimensional methods. Two electrode metrics were determined for each bone: the inserted length (IL: the distance measured from the cochleostomy site to the apical tip of the electrode) and the active electrode length (AEL: the distance between the most basal and most apical electrodes on the electrode array). The ratio of these two metrics (IL/AEL) was used to split the temporal bones into two groups: those with incomplete insertion (n = 27, IL/AEL Results: Obvious obstruction by abnormal intracochlear bone or soft tissue accounted for only 6 (22%) of the 27 partial insertions. Of the remaining 21 bones with incomplete insertions and 13 bones with complete insertions, dissection of the spiral ligament to the lateral cochlear wall was the only histopathologic indicator of insertion resistance identified with significantly higher frequency in the partial-insertion bones than in the complete-insertion bones (p = 0.003). An observed trend for the percentage of complete insertions to decrease with the number of times the electrode penetrated the basilar membrane did not reach significance. In the bones without an obvious obstruction, the most frequently observed indicator of insertion resistance was dissection of the spiral ligament (with no contact of the lateral cochlear wall) identified in 67% (14/21) of partial-insertion bones and in 92% (12/13) of complete-insertion bones. Conclusion: These results are consistent with the view that (1) electrode contact with cochlear structures resulting in observable trauma to the basilar membrane, osseous spiral lamina and/or spiral ligament does not necessarily impact the likelihood of complete insertion of the electrode array and (2) once contact trauma to the spiral ligament reaches the point of dissection to the cochlear wall, the likelihood of incomplete insertion increases dramatically.Keywords
This publication has 20 references indexed in Scilit:
- Foreign Body or Hypersensitivity Granuloma of the Inner Ear After Cochlear Implantation: One Possible Cause of a Soft Failure?Otology & Neurotology, 2008
- A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour™ electrodesHearing Research, 2005
- Histologic Evaluation of the Tissue Seal and Biologic Response Around Cochlear Implant Electrodes in the HumanOtology & Neurotology, 2004
- Effects of Insertion Depth of Cochlear Implant Electrodes upon Speech PerceptionAudiology and Neurotology, 2004
- Temporal Bone Histopathology Related to Cochlear Implantation in Congenital Malformation of the Bony CochleaOtology & Neurotology, 2002
- CT-Derived Estimation of Cochlear Morphology and Electrode Array Position in Relation to Word Recognition in Nucleus-22 RecipientsJournal of the Association for Research in Otolaryngology, 2002
- Histopathology of Cochlear Implants in HumansAnnals of Otology, Rhinology & Laryngology, 2001
- Multichannel intracochlear electrodes: Mechanism of insertion traumaThe Laryngoscope, 1987
- Histologic variants in otosclerosisThe Laryngoscope, 1985
- Histological Considerations in Implant PatientsJAMA Otolaryngology–Head & Neck Surgery, 1984