Validation of a new objective index to measure spinal mobility: the University of Cordoba Ankylosing Spondylitis Metrology Index (UCOASMI)
- 20 December 2013
- journal article
- research article
- Published by Springer Nature in Rheumatology International
- Vol. 34 (3) , 401-406
Abstract
Spinal mobility measures are subject to high variability and subjectivity. Automated motion capture allows an objective and quantitative measure of mobility with high levels of precision. To validate the University of Cordoba Ankylosing Spondylitis Metrology Index (UCOASMI), an index measure of spinal mobility, based on automated motion capture, validation studies included the following: (1) validity, tested by correlation—Pearson’s r—between the UCOASMI and the mobility index Bath Ankylosing Spondylitis Metrology Index (BASMI), and a measure of structural damage, the modified Stoke Ankylosing Spondylitis Spinal Score (mSASSS); (2) reliability, with internal consistency tested by Cronbach’s alpha, test–retest by intraclass correlation coefficient (ICC) after 2 weeks, and error measurement, by variation coefficient (VC) and smallest detectable difference (SDD); and (3) responsiveness, by effect size (ES) in a clinical trial of anti-TNF. Patients for the different studies all had ankylosing spondylitis. Validity studies show correlation between the BASMI (r = 0.881) and the mSASSS (r = 0.780). Reliability studies show an internal consistency of Cronbach’s α = 0.894, intra-observer ICC = 0.996, test–retest ICC = 0.996, and a measurement error of VC = 2.80 % and SDD = 0.25 points. Responsiveness showed an ES after 24 weeks of treatment of 0.48. In all studies, the UCOASMI’s performance was better than that of the BASMI. The UCOASMI is a validated index to measure spinal mobility with better metric properties than previous indices.Keywords
This publication has 16 references indexed in Scilit:
- Assessment of spinal mobility in ankylosing spondylitis using a video-based motion capture systemManual Therapy, 2012
- Validity and Reliability of the Metric Measurements in the Assessment of Lumbar Spine Motion in Patients With Ankylosing SpondylitisSpine, 2012
- An exploration of the inter- and intra-rater reliability of the Bath Ankylosing Spondylitis Metrology IndexClinical Rheumatology, 2012
- The Bath metrology index as assessed by a trained and an untrained rater in patients with spondylarthropathy: a study of intra- and inter-rater agreementsClinical Rheumatology, 2008
- Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic reviewEuropean Spine Journal, 2008
- Design and evaluation of a new three-dimensional motion capture system based on videoGait & Posture, 2006
- Development and validation of the Edmonton Ankylosing Spondylitis Metrology IndexArthritis Care & Research, 2006
- Zebris Versus Myrin: A Comparative Study Between a Three-Dimensional Ultrasound Movement Analysis and an Inclinometer/Compass MethodSpine, 2003
- Evaluation of the smallest detectable difference in outcome or process variables in ankylosing spondylitisArthritis Care & Research, 2002
- Evaluation of Diagnostic Criteria for Ankylosing SpondylitisArthritis & Rheumatism, 1984