Left ventricular twist: comparison between two- and three-dimensional speckle-tracking echocardiography in healthy volunteers
Authors:
- J. AndradeJAJ. Andrade
- L. D. CortezLCL. D. Cortez
- O. CamposOCO. Campos
- A. L. ArrudaAAA. L. Arruda
- J. PinheiroJPJ. Pinheiro
- L. VulcanisLVL. Vulcanis
- T. S. ShiratsuchiTST. S. Shiratsuchi
- R. Kalil-FilhoRKR. Kalil-Filho
- G. G. CerriGCG. G. Cerri
- 3 September 2010
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 12 (1) , 76-79
Abstract
Left ventricular (LV) twist is the result of clockwise rotation of the base and counterclockwise rotation of the apex. The aims of this study were to investigate the feasibility of the three-dimensional speckle-tracking echocardiography (3DSTE) to assess LV twist values and compare the data measured by two-dimensional speckle-tracking echocardiography (2DSTE) in a group of healthy volunteers. fifty individuals were enrolled in the protocol. LV twist was defined as net difference between averaged 2DSTE apical (4 segments) and basal (6 segments) rotations. 3DSTE twist was obtained from the LV volumetric image and shown as the averaged global value of 16 segments. Time-to-peak by both techniques was also measured and compared. Significant differences between the two techniques were calculated using the paired Student t-test. P-values of <0.05 were considered significant. Reliable LV twist measurement was possible in 39 of 50 individuals (78%). 2DSTE twist mean peak value was 13.8 + 7.9° with a mean time-to-peak of 388.3 ± 152.3 ms and global 3DSTE twist mean peak value was 10.2 + 7.6° with a mean time-to-peak of 371.8 ± 127.5 ms. Peak LV twist values by 3DSTE was significantly smaller than by 2DSTE (P < 0.01) whereas time-to-peak results showed no significant difference. 3DSTE is feasible to assess LV twist deformation. Whereas further investigations using 3DSTE are needed to validate this promising technology, comparing 2DSTE and 3DSTE should be done with caution, as values for peak LV twist differ.Keywords
This publication has 21 references indexed in Scilit:
- Usefulness of Three-Dimensional Speckle Tracking Strain to Quantify Dyssynchrony and the Site of Latest Mechanical ActivationThe American Journal of Cardiology, 2010
- Quantitative Evaluation of Regional Left Ventricular Function Using Three-Dimensional Speckle Tracking Echocardiography in Patients With and Without Heart DiseaseThe American Journal of Cardiology, 2009
- Validation of 3-Dimensional Speckle Tracking Imaging to Quantify Regional Myocardial DeformationCirculation: Cardiovascular Imaging, 2009
- Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRIEuropean Heart Journal, 2009
- Apical Rotation by Speckle Tracking Echocardiography: A Simplified Bedside Index of Left Ventricular TwistJournal of the American Society of Echocardiography, 2008
- Doin’ the twist: new tools for an old concept of myocardial functionHeart, 2008
- Echocardiographic quantification of myocardial function using tissue deformation imaging, a guide to image acquisition and analysis using tissue Doppler and speckle trackingCardiovascular Ultrasound, 2007
- Assessment of Left Ventricular Rotation and Torsion with Two-dimensional Speckle Tracking EchocardiographyJournal of the American Society of Echocardiography, 2007
- The helical ventricular myocardial band: global, three-dimensional, functional architecture of the ventricular myocardium☆European Journal of Cardio-Thoracic Surgery, 2006
- New Noninvasive Method for Assessment of Left Ventricular RotationCirculation, 2005