A MEMS Device Capable of Measuring Near-Field Thermal Radiation between Membranes
Open Access
- 4 February 2013
- Vol. 13 (2) , 1998-2010
Abstract
For sensors constructed by freestanding membranes, when the gap between a freestanding membrane and the substrate or between membranes is at micron scale, the effects of near-field radiative heat transfer on the sensors’ thermal performance should be considered during sensor design. The radiative heat flux is transferred from a membrane to a plane or from a membrane to a membrane. In the current study of the near-field thermal radiation, the scanning probe technology has difficulty in making a membrane separated at micron scale parallel to a plane or another membrane. A novel MEMS (micro electromechanical system) device was developed by sacrificial layer technique in this work to realize a double parallel freestanding membrane structure. Each freestanding membrane has a platinum thin-film resistor and the distance between the two membranes is 1 m. After evaluating the electrical and thermal characteristics of the lower freestanding membrane, experimental measurements of near-field radiative heat transfer between the lower membrane and the upper membrane were carried out by setting the lower membrane as a heat emitter and the upper membrane as a heat receiver. The near-field radiative heat transfer between the two membranes was validated by finding a larger-than-blackbody radiative heat transfer based on the experimental data.Keywords
This publication has 26 references indexed in Scilit:
- Fabrication and Characterization of CMOS-MEMS Thermoelectric Micro GeneratorsSensors, 2010
- A MicroPirani Pressure Sensor Based on the Tungsten Microhotplate in a Standard CMOS ProcessIEEE Transactions on Industrial Electronics, 2009
- An ac microcalorimeter for measuring specific heat of thin filmsMicroelectronics Journal, 2004
- Anemometer with hot platinum thin filmSensors and Actuators A: Physical, 2001
- Low-cost 320x240 uncooled IRFPA using a conventional silicon IC process1999
- A high fill-factor infrared bolometer using micromachined multilevel electrothermal structuresIEEE Transactions on Electron Devices, 1999
- Realization and performance of thin SiO2/SiNx membrane for microheater applicationsSensors and Actuators A: Physical, 1998
- Monolithic two-dimensional arrays of micromachined microstructures for infrared applicationsProceedings of the IEEE, 1998
- A silicon-silicon nitride membrane fabrication process for smart thermal sensorsSensors and Actuators A: Physical, 1994
- Experimental Investigation of Radiative Transfer Between Metallic Surfaces at Cryogenic TemperaturesJournal of Heat Transfer, 1970