Gd-EOB enhanced MRI T1-weighted 3D-GRE with and without elevated flip angle modulation for threshold-based liver volume segmentation
- 18 November 2014
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (12) , 1419-1427
Abstract
Despite novel software solutions, liver volume segmentation is still a time-consuming procedure and often requires further manual optimization. With the high signal intensity of the liver parenchyma in Gd-EOB enhanced magnetic resonance imaging (MRI), liver volume segmentation may be improved. To evaluate the practicability of threshold-based segmentation of the liver volume using Gd-EOB-enhanced MRI including a customized three-dimensional (3D) sequence. A total of 20 patients examined with Gd-EOB MRI (hepatobiliary phase T1-weighted (T1W) 3D sequence [VIBE]; flip angle [FA], 10° and 30°) were enrolled in this retrospective study. The datasets were independently processed by two blinded observers (O1 and O2) in two ways: manual (man) and threshold-based (thresh; study method) segmentation of the liver each followed by an optimization step (man+opt and thresh+opt; man+opt [FA10°] served as reference method). Resulting liver volumes and segmentation times were compared. A liver conversion factor was calculated in percent, describing the non-hepatocellular fraction of the total liver volume, i.e. bile ducts and vessels. Thresh+opt (FA10°) was significantly faster compared to the reference method leading to a median volume overestimation of 4%/8% (P < 0.001). Using thresh+opt (FA30°), segmentation was even faster (P < 0.001) and even reduced median volume deviation of 0%/2% (O1/O2; both P > 0.2). The liver conversion factor was found to be 10%. Threshold-based liver segmentation employing Gd-EOB-enhanced hepatobiliary phase standard T1W 3D sequence is accurate and time-saving. The performance of this approach can be further improved by increasing the FA.Keywords
This publication has 28 references indexed in Scilit:
- Automated Liver Volumetry in Orthotopic Liver Transplantation Using Multiphase Acquisitions on MDCTAmerican Journal of Roentgenology, 2012
- Living Donor Right Liver Lobes: Preoperative CT Volumetric Measurement for Calculation of Intraoperative Weight and VolumeRadiology, 2006
- Liver Tumor CharacterizationJournal of Computer Assisted Tomography, 2006
- Liver and Spleen Volumetry with Quantitative MR Imaging and Dual-Space Clustering SegmentationRadiology, 2005
- Efficacy and Safety of MR Imaging with Liver-specific Contrast Agent: U.S. Multicenter Phase III StudyRadiology, 2005
- Liver Segmentation in Living Liver Transplant Donors: Comparison of Semiautomatic and Manual MethodsRadiology, 2005
- Voraussagegenauigkeit der präoperativen CT-gestützten Gewichtsbestimmung des rechten Leberlappens bezüglich des intraoperativen Transplantatgewichts bei Leberlappen-LebendspendernRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2003
- Fully Automatic Anatomical, Pathological, and Functional Segmentation from CT Scans for Hepatic SurgeryComputer Aided Surgery, 2001
- CT-Volumetrie der Leber vor TransplantationRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1997
- Reliability and exactness of MRI‐based volumetry: A phantom studyJournal of Magnetic Resonance Imaging, 1996