Drop size correlation and population balance model for an agitated‐pulsed solvent extraction column
- 23 May 2020
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 66 (8)
Abstract
Agitated‐pulsed column (APC) is a newly designed extraction column with excellent mass transfer performance. In this work, Sauter mean drop diameter d32 and drop size distribution was investigated under different operation conditions in a 25 mm diameter APC. The results show that with an increase in pulsation intensity and agitation speed the drop size distribution is narrowed and d32 is decreased significantly. With increasing dispersed‐phase velocity, d32 increased and drop size distribution become narrow, while there was no noticeable change with continuous velocity. The cumulative size distribution was found to be predicted well using the Inverse Gaussian function. A new correlation was proposed to predict the experimental d32 data of the APC column used in this study. Furthermore, population balance model was applied to predict the drop size distribution with refitted parameters in the breakage, coalescence kernels functions.Keywords
This publication has 37 references indexed in Scilit:
- CFD–PBM simulation of two-phase flow in a pulsed disc and doughnut column with directly measured breakup kernel functionsChemical Engineering Science, 2019
- CFD-PBM simulations of a pulsed sieve plate columnProgress in Nuclear Energy, 2019
- Prediction of holdup and drop size distribution in a disc-doughnut pulsed column with tenova kinetics internals for the water-Alamine 336 systemHydrometallurgy, 2018
- Hydrodynamic Performance of a Pulsed Solvent Extraction Column with Novel Ceramic Internals: Holdup and Drop SizeIndustrial & Engineering Chemistry Research, 2017
- Using maximum entropy, Gamma, Inverse Gaussian and Weibull approach for prediction of drop size distribution in a liquid–liquid extraction columnChemical Engineering Research and Design, 2017
- Development of a CFD–PBE coupled model for the simulation of the drops behaviour in a pulsed columnThe Canadian Journal of Chemical Engineering, 2013
- Population Balance Modeling of Pulsed (Packed and Sieve-Plate) Extraction Columns: Coupled Hydrodynamic and Mass TransferIndustrial & Engineering Chemistry Research, 2011
- Industrial Scale Natural Products Extraction2011
- Drop size distributions in liquid pulsed columnsBioprocess and Biosystems Engineering, 1997
- Unified Correlations for the Prediction of Drop Size in Liquid−Liquid Extraction ColumnsIndustrial & Engineering Chemistry Research, 1996