Abstract
We compared the performance of a channelized Hotelling observer (CHO) to that of human observers to determine an optimal smoothing parameter /spl beta/ for an SKE/BKE detection task in a SPECT MAP (maximum a posteriori) reconstruction. The study is motivated in part by the recent development of theoretical methods that can rapidly predict CHO signal-to-noise ratios (SNRs) for MAP reconstructions. We found that a CHO not adjusted for internal noise effects was less predictive of the optimal smoothing parameters than one that used human observer data to tune the CHO for internal noise. We used a three-channel, square profile, radially symmetric channel structure, and, for internal noise, a method that altered the diagonal elements of the channel covariance matrix. The human observer study for two different signals A and B showed that /spl beta/ in the range 0.5-10.0 produced high detectability as measured by high d/sub A//sup 2/, while the CHO without internal noise showed high SNR/sup 2/ for /spl beta/ in the wider range 0.01-10.0. The CHO at location A was modified by internal noise utilizing human data at A, so that the d/sub A//sup 2/ and SNR/sup 2/ overlapped well, but when these internal noise parameters from A were applied at B, the curves did not overlap well. Nevertheless, both modified CHOs predicted a /spl beta/ range in accord with human data. We conclude that CHOs may need some way of incorporating internal noise without having to conduct a human study in the first place to determine internal noise parameters.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of channelized hotelling and human observers in determining optimum OSEM reconstruction parameters for myocardial SPECT2004
- Rapid calculation of detectability in Bayesian single photon emission computed tomographyPhysics in Medicine & Biology, 2003
- Optimization of iterative reconstructions of /sup 99m/Tc cardiac SPECT studies using numerical observersIEEE Transactions on Nuclear Science, 2002
- Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECTIEEE Transactions on Medical Imaging, 2002
- Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variabilityJournal of the Optical Society of America A, 2001
- Covariance approximation for fast and accurate computation of channelized Hotelling observer statisticsIEEE Transactions on Nuclear Science, 2000
- Using a digital anatomical phantom to optimize an imaging system1999
- A theoretical study of the contrast recovery and variance of MAP reconstructions from PET dataIEEE Transactions on Medical Imaging, 1999
- The bootstrap and its application in signal processingIEEE Signal Processing Magazine, 1998
- Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographsIEEE Transactions on Image Processing, 1996