Heartbeat detection with Doppler radar based on estimation of average R-R interval using Viterbi algorithm
Authors:
- 1 September 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Abstract
Vital signs are related to mental stress conditions. In particular, the variation of R-R interval (the peak-to-peak interval of heartbeats) reflects mental stress. For measuring heart rate, non-contact detection using Doppler radar has been studied in many works. In this paper, we propose an algorithm to detect periodic heartbeats for some periods in which the R-R intervals are almost equal. In the long term, the R-R intervals gradually vary, however, the R-R intervals are almost equal within a short period. To detect those periods, we assume that the R-R intervals always have almost equal intervals. Then, we detect periodic peaks appearing at almost the equal intervals by using the Viterbi algorithm. After detecting periodic peaks, we detect the periods during which the R-R intervals are almost equal, based on the variance of the detected peak-to-peak intervals. Moreover, we estimate an average R-R interval and find peaks that appear at the interval nearly equal to the estimated average R-R interval within each detected period. Experimental results show that the proposed algorithm improves RMSEs (root mean square error) of the R-R interval compared with the conventional methods.Keywords
This publication has 10 references indexed in Scilit:
- Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar SensorIEEE Transactions on Biomedical Engineering, 2013
- 1-D Microwave Imaging of Human Cardiac Motion: An Ab-Initio InvestigationIEEE Transactions on Microwave Theory and Techniques, 2013
- 40-GHz vital sign detection of heartbeat using synchronized motion technique for respiration signal suppression2012
- Non-contact heart rate detection using periodic variation in Doppler frequency2011
- Separating respiration artifact in microwave doppler radar heart monitoring by Independent Component Analysis2010
- Multitunable microwave system for touchless heartbeat detection and heart rate variability extractionMicrowave and Optical Technology Letters, 2009
- A Tunable System for Contact-Less Heartbeat Detection and a Modeling Approach2009
- Experiment and Spectral Analysis of a Low-Power $Ka$-Band Heartbeat Detector Measuring From Four Sides of a Human BodyIEEE Transactions on Microwave Theory and Techniques, 2006
- Range Correlation and$ I/ Q$Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary MonitoringIEEE Transactions on Microwave Theory and Techniques, 2004
- 0.25 μm CMOS and BiCMOS single-chip direct-conversion Doppler radars for remote sensing of vital signs2003