Central venous catheter sampling of low molecular heparin levels
Authors:
- Mark BelletruttiMBMark Belletrutti
- M. L. BaumanMBM. L. Bauman
- M. P. MassicotteMMM. P. Massicotte
- 1 January 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 13 (1) , 1-5
Abstract
The low molecular weight heparin effect in children is monitored using the anti-factor Xa level. Venipuncture is recommended; however, central venous catheter blood sampling is often necessary. Heparin infused through central venous catheters may contaminate central venous catheter blood samples, preventing reliable anti-factor Xa level measurement. Simultaneous anti-factor Xa/partial thromboplastin time measurement with central venous catheter blood sampling may predict anti-factor Xa reliability. To determine the prevalence of heparin contamination as measured by the partial thromboplastin time/anti-factor Xa in central venous catheter blood samples and whether careful sampling could minimize heparin contamination of anti-factor Xa levels from central venous catheter blood sampling. Simultaneous partial thromboplastin time/anti-factor Xa measurements from central venous catheter blood sampling determined the prevalence of heparin contamination of central venous catheter blood samples. In phase II, children receiving low molecular weight heparin had routine central venous catheter blood sampling to measure the peak anti-factor Xa and the simultaneous partial thromboplastin time. Anti-factor Xa levels with a partial thromboplastin time of >40 secs (pair 1) were identified; there was no low molecular weight heparin dose change, and the paired sample was repeated using a careful sampling technique (pair 2). Pairs 1 and 2 were compared to determine the efficiency of the sampling technique in removing heparin from the central venous catheter blood samples. In phase I, 100 children had 485 paired anti-factor Xa/partial thromboplastin time central venous catheter blood samples with 29% ± 4.1% (95% confidence interval 25% to 33%) anti-factor Xa with partial thromboplastin times of >40 secs. In phase II, 43 children had 129 paired anti-factor Xa/partial thromboplastin time samples with partial thromboplastin times of >40 secs. The pair 1 mean partial thromboplastin times/anti-factor Xa levels were 109.8 secs (SD 53.1, range 34.0 to >200 secs) and 1.03 units/mL (SD 0.56, range 0.26-4.2 units/mL). Repeated partial thromboplastin times/anti-factor Xa levels (pair 2) were significantly decreased from those of pair 1 (p < .001) with means of 58.5 secs (SD 21.2, range 22-152 secs) vs. 109.8 secs (SD 53.1, range 34.0 to > 200 secs, p < .001) and 0.63 unit/mL (SD 0.30, range 0.02-1.77 units/mL) vs. 1.03 units/mL (SD 0.56, range 0.26-4.2 units/mL), respectively. Measurement of the partial thromboplastin time performed in combination with that of the anti-factor Xa level can be used to assist health practitioners to identify unfractionated heparin contamination of anti-factor Xa levels drawn from central venous catheters. A careful sampling technique may minimize heparin contamination in central venous catheter blood samples.Keywords
This publication has 22 references indexed in Scilit:
- Novel uses of insulin syringes to reduce dosing errors: A retrospective chart review of enoxaparin whole milligram dosingThrombosis Research, 2009
- Evaluation of enoxaparin dosing requirements in infants and childrenThrombosis and Haemostasis, 2009
- Antithrombotic Therapy in Neonates and ChildrenChest, 2008
- Parenteral AnticoagulantsChest, 2008
- Dose-finding and pharmacokinetics of therapeutic doses of tinzaparin in pediatric patients with thromboembolic eventsThrombosis and Haemostasis, 2005
- Low Molecular Weight Heparin in the Treatment of Venous and Arterial Thromboses in the Premature InfantPediatrics, 2004
- An open-label randomized controlled trial of low molecular weight heparin compared to heparin and coumadin for the treatment of venous thromboembolic events in children: the REVIVE trialThrombosis Research, 2003
- Low molecular weight heparin in childrenEuropean Journal of Pediatrics, 2001
- Heparin and Low-Molecular-Weight Heparin Mechanisms of Action, Pharmacokinetics, Dosing, Monitoring, Efficacy, and SafetyChest, 2001
- The use of low molecular weight heparin in pediatric patients: A prospective cohort studyThe Journal of Pediatrics, 2000