Characterization of normal regional myocardial function by MRI cardiac tagging
- 12 December 2013
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 41 (1) , 83-92
Abstract
Purpose The aim of this study was to establish reference values for segmental myocardial strain measured by magnetic resonance (MR) cardiac tagging in order to characterize the regional function of the heart. Material and Methods We characterized the left ventricular (LV) systolic deformation in 39 subjects (26 women and 13 men, age 58.8 ± 11.6 years) whose cardiological study had not revealed any significant abnormality. The deformation was measured from MR‐tagged (Siemens 1.5T MR) images using an algorithm based on sine wave modeling. Circumferential and radial peak systolic strain values along with the torsion angle and circumferential‐longitudinal (CL) shear were determined in 16 LV segments in order to settle the reference values for these parameters. Results Circumferential strain was highest at the anterior and lateral walls (−20.2 ± 4.0% and −21.8 ± 4.3%, respectively; P < 0.05) and was lowest at the base level (−17.2 ± 3.1% vs. −20.1 ± 3.1% “mid level,” P < 0.05; −17.2 ± 3.1% vs. −20.3 ± 3.0% “apical level,” P < 0.05). Radial strain highest values were from inferior and lateral walls (13.7 ± 7.4% and 12.8 ± 7.8%, respectively; P < 0.05) and it was lowest medially (9.4 ± 4.1% vs. 13.1 ± 4.1% “base level,” P < 0.05; 9.4 ± 4.1% vs. 12.1 ± 4.4% “apical level,” P < 0.05). Torsion angle (counterclockwise when viewed from the apex) increased with the distance from the base (7.9 ± 2.4° vs. 16.8 ± 4.4°, P < 0.05), and the highest and lowest values were found at lateral (medial lateral: 12.0 ± 4.4°, apical lateral: 25.1 ± 6.4°, P < 0.05) and septal wall (medial septal: 3.6 ± 2.1°, apical septal: 8.3 ± 5.3°, P < 0.05), respectively. These differences were found again in CL shear values, around the LV circumference. However, CL shear remained constant with increasing distance from the base (9.1 ± 2.6°, medium and 9.8 ± 2.4°, apex). Conclusion In summary, this study provides reference values for the assessment of regional myocardial function by MR cardiac tagging. Comparison of patient deformation parameters with normal deformation patterns may permit early detection of regional systolic dysfunction. J. Magn. Reson. Imaging 2015;41:83–92.Keywords
This publication has 51 references indexed in Scilit:
- Comparison of local sine wave modeling with harmonic phase analysis for the assessment of myocardial strainJournal of Magnetic Resonance Imaging, 2012
- Comparison of cardiac MRI tissue tracking and myocardial tagging for assessment of regional ventricular strainThe International Journal of Cardiovascular Imaging, 2012
- Left ventricular torsion, energetics, and diastolic function in normal human agingAmerican Journal of Physiology-Heart and Circulatory Physiology, 2012
- Evaluation of Techniques for the Quantification of Myocardial Scar of Differing Etiology Using Cardiac Magnetic ResonanceJACC: Cardiovascular Imaging, 2011
- Myocardial tagging by Cardiovascular Magnetic Resonance: evolution of techniques–pulse sequences, analysis algorithms, and applicationsJournal of Cardiovascular Magnetic Resonance, 2011
- Magnetic resonance imaging detects significant sex differences in human myocardial strainBioMedical Engineering OnLine, 2011
- Regional myocardial contractile function: multiparametric strain mapping☆Interactive CardioVascular and Thoracic Surgery, 2010
- Myocardial tissue tagging with cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2009
- The effect of anteroapical aneurysm plication on end-systolic three-dimensional strain in the sheep: A magnetic resonance imaging tagging studyThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Three-Dimensional Myocardial Strains at End-Systole and During Diastole in the Left Ventricle of Normal HumansJournal of Cardiovascular Magnetic Resonance, 2002