Ultrasonic Trapping of Microparticles in Suspension and Reaction Monitoring Using Raman Microspectroscopy
- 18 September 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (20) , 7853-7857
Abstract
An ultrasonic standing wave around 2 MHz has been used for trapping and concentration of suspended micrometer-size particles in a flow cell, whereas Raman microspectroscopy was used as a nondestructive technique to provide molecular information about the trapped particles. With this approach, detection and discrimination of different polymer microparticles based on their characteristic Raman spectra was performed. Dextran, poly(vinyl alcohol), and melamine resin-based beads, with and without functionalization, were used for this purpose. Furthermore, taking advantage of the flow-through characteristics of the cell and the versatility of the employed flow system, full control over the media surrounding the trapped particles was achieved. This allowed us to perform chemical reactions on the trapped particles and to monitor spectral changes in real time. Here retention of cation-exchanger beads loaded with silver ions and subsequent reduction of the silver ions was demonstrated. In this way, surface-enhanced Raman (SER) active beads were prepared and retained in the focus of the Raman microscope by means of the ultrasonic field. Injection of analytes in the flow system thus allowed recording of their SER spectra. Using 9-aminoacridine, a linear dependence of the found SER signal in the range from 1 to 10 μM has been achieved. The repeatability in the recorded SER intensities was on the order of 4−5%. This included bead retention, surface-enhanced Raman layer synthesis, and analyte detection.Keywords
This publication has 22 references indexed in Scilit:
- Containerless reaction monitoring in ionic liquids by means of Raman microspectroscopyLab on a Chip, 2006
- Characterisation of spatial and temporal changes in pH gradients in microfluidic channels using optically trapped fluorescent sensorsLab on a Chip, 2006
- Nanotube and DNA ion channels. | Intracellular imaging with Raman. | Microwaving proteins. | Microfluidic flow without pressure. | Xenon as an NMR biosensor. | Solid-state NMR of proteins. | Substrate for disposable microarrays. | Bright carbon nanotubes. | Patterned lipid bilayers.Analytical Chemistry, 2005
- Adsorption of acridine drugs on silver: surface-enhanced resonance Raman evidence of the existence of different adsorption sitesVibrational Spectroscopy, 2001
- Chemical Reactions of Single Levitated Inorganic Salt Particles with Ammonia GasApplied Spectroscopy, 2000
- Investigations of chemical reactions between single levitated magnesium chloride microdroplets with SO2 and NOx by means of Raman spectroscopy and elastic light scatteringPhysical Chemistry Chemical Physics, 1999
- Formation and growth of ice particles in stationary ultrasonic fieldsThe Journal of Chemical Physics, 1998
- Raman Vibrational Evidence for the Presence of Conjugated Regions in Individual Micron Diameter Polystyrene Particles Irradiated with Visible RadiationThe Journal of Physical Chemistry B, 1998
- Determination of free melamine content in melamine-formaldehyde resins by Raman spectroscopyVibrational Spectroscopy, 1995
- Raman-Microsampling Technique Applying Optical Levitation by Radiation PressureApplied Spectroscopy, 1984