C-arm technique with distance driven for nephrolithiasis and kidney stones detection: Preliminary study
- 1 February 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 164-167
Abstract
Kidney stone is among the common painful disorders of the urinary system. The presence of stones in the kidney refers to Nephrolithiasis. For nephrolithiasis and kidney stones detection, a C-arm tomographic technique was investigated in this paper to generate three dimensional kidney structural information. A series of two dimensional (2D) x-ray projection images were acquired by moving the x-ray tube to different positions around the object over limited angular view with C-arm gantry. The results of our experiments were obtained by using a kidney phantom with low radiation dosage. Reconstruction algorithms based on distance driven (DD) method were developed for C-arm tomographic technique. Computer simulation study was done with simulated tomographic project images of spherical objects to evaluate the performance of each reconstruction algorithm. Preliminary results showed the capability to generate volume information of the kidney for nephrolithiasis and kidney stone detection.Keywords
This publication has 12 references indexed in Scilit:
- C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applicationsLa radiologia medica, 2014
- Calibration of a C-arm X-Ray System for Its Use in Tomography2014
- Intraoperative Cone‐Beam Computed Tomography and Multi‐Slice Computed Tomography in Temporal Bone Imaging for Surgical TreatmentOtolaryngology–Head and Neck Surgery, 2013
- Intraoperative C‐arm cone‐beam computed tomography: Quantitative analysis of surgical performance in skull base surgeryThe Laryngoscope, 2012
- Multi-beam x-ray source breast tomosynthesis reconstruction with different algorithms2010
- Breast tomosynthesis reconstruction with a multi-beam x-ray source2009
- C-arm Cone-beam CT: General Principles and Technical Considerations for Use in Interventional RadiologyJournal of Vascular and Interventional Radiology, 2008
- Importance of point‐by‐point back projection correction for isocentric motion in digital breast tomosynthesis: Relevance to morphology of structures such as microcalcificationsMedical Physics, 2007
- Distance-driven projection and backprojection in three dimensionsPhysics in Medicine & Biology, 2004
- Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional proceduresIEEE Transactions on Medical Imaging, 2000