Fracture of the cricoid cartilage after Sellick's manoeuvre

Authors:
  • MPM Palmer
    M Palmer
  • SFS J Fletcher
    S J Fletcher

Abstract
We report a case of fracture of the cricoid cartilage associated with cricoid pressure during rapid sequence tracheal intubation in a patient with status asthmaticus. This patient had a history of laryngeal trauma 48 yr previously. Fracture of the cricoid cartilage has not been reported previously after cricoid pressure.