Evaluation of cuff deflation and inflation rates on a deep learning-based automatic blood pressure measurement method: a pilot evaluation study
Authors:
- 23 November 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 26 (2) , 129-134
Abstract
Objective: The aim of this study was to evaluate the performance of using a deep learning-based method for measuring SBPs and DBPs and the effects of cuff inflation and deflation rates on the deep learning-based blood pressure (BP) measurement (in comparison with the manual auscultatory method). Methods: Forty healthy subjects were recruited. SBP and DBP were measured under four conditions (i.e. standard deflation, fast deflation, slow inflation and fast inflation) using both our newly developed deep learning-based method and the reference manual auscultatory method. The BPs measured under each condition were compared between the two methods. The performance of using the deep learning-based method to measure BP changes was also evaluated. Results: There were no significant BP differences between the two methods (P > 0.05), except for the DBPs measured during the slow and fast inflation conditions. By applying the deep learning-based method, SBPs measured from fast deflation, slow inflation and fast inflation decreased significantly by 3.0, 3.5 and 4.7 mmHg (all P < 0.05), respectively, in comparison with the standard deflation condition. Whereas, corresponding DBPs measured from the slow and fast inflation conditions increased significantly by 5.0 and 6.8 mmHg, respectively (both P < 0.05). There were no significant differences in BP changes measured by the two methods in most cases (all P > 0.05, except for DBP change in the slow and fast inflation conditions). Conclusion: This study demonstrated that the deep learning-based method can achieve accurate BP measurement under the deflation and inflation conditions with different rates.Keywords
This publication has 21 references indexed in Scilit:
- Blood pressure monitoringBlood Pressure Monitoring, 2018
- Comparison of inflationary non-invasive blood pressure (iNIBP) monitoring technology and conventional deflationary non-invasive blood pressure (dNIBP) measurement in detecting hypotension during cesarean sectionJA Clinical Reports, 2018
- How Important is the Recommended Slow Cuff Pressure Deflation Rate for Blood Pressure Measurement?Annals of Biomedical Engineering, 2011
- Principles and Techniques of Blood Pressure MeasurementCardiology Clinics, 2010
- Accuracy of inflationary versus deflationary oscillometry in pregnancy and preeclampsia: OMRON-MIT versus OMRON-M7Blood Pressure Monitoring, 2009
- Recommendations for Blood Pressure Measurement in Humans and Experimental AnimalsCirculation, 2005
- Guidelines for management of hypertension: report of the fourth working party of the British Hypertension Society, 2004—BHS IVJournal of Human Hypertension, 2004
- Measuring Blood Pressure AccuratelyJAMA, 2003
- The Working Group on Blood Pressure Monitoring of the European Society of HypertensionBlood Pressure Monitoring, 2003
- Influence of rate of cuff inflation and deflation on observed blood pressure by sphygmomanometryAmerican Heart Journal, 1963