Evaluation of measurement uncertainties in human diffusion tensor imaging (DTI)‐derived parameters and optimization of clinical DTI protocols with a wild bootstrap analysis
Authors:
- Michelle D. GaughMGMichelle D. Gaugh
- Jianhui ZhongJZJianhui Zhong
Open Access
- 22 January 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 29 (2) , 422-435
Abstract
Purpose To quantify measurement uncertainties of fractional anisotropy, mean diffusivity, and principal eigenvector orientations in human diffusion tensor imaging (DTI) data acquired with common clinical protocols using a wild bootstrap analysis, and to establish optimal scan protocols for clinical DTI acquisitions. Materials and Methods A group of 13 healthy volunteers were scanned using three commonly used DTI protocols with similar total scan times. Two important parameters—the number of unique diffusion gradient directions (NUDG) and the ratio of the total number of diffusion-weighted (DW) images to the total number of non-DW images (DTIR)—were analyzed in order to investigate their combined effects on uncertainties of DTI-derived parameters, using results from both the Monte Carlo simulation and the wild bootstrap analysis of uncertainties in human DTI data. Results The wild bootstrap analysis showed that uncertainties in human DTI data are significantly affected by both NUDG and DTIR in many brain regions. These results agree with previous predictions based on error-propagations as well as results from simulations. Conclusion Our results demonstrate that within a clinically feasible DTI scan time of about 10 minutes, a protocol with number of diffusion gradient directions close to 30 provides nearly optimal measurement results when combined with a ratio of the total number of DW images over non-DW images equal to six. Wild bootstrap can serve as a useful tool to quantify the measurement uncertainty from human DTI data. J. Magn. Reson. Imaging 2009;29:422–435.Keywords
This publication has 35 references indexed in Scilit:
- An optimized wild bootstrap method for evaluation of measurement uncertainties of DTI-derived parameters in human brainNeuroImage, 2008
- Diffusion Tensor Imaging Detects Clinically Important Axonal Damage after Mild Traumatic Brain Injury: A Pilot StudyJournal of Neurotrauma, 2007
- Effects of signal‐to‐noise ratio on the accuracy and reproducibility of diffusion tensor imaging–derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5TJournal of Magnetic Resonance Imaging, 2007
- Comparison of bootstrap approaches for estimation of uncertainties of DTI parametersNeuroImage, 2006
- Regional distribution of measurement error in diffusion tensor imagingPsychiatry Research: Neuroimaging, 2006
- Assessing DTI data quality using bootstrap analysisMagnetic Resonance in Medicine, 2004
- Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brainJournal of Magnetic Resonance Imaging, 2003
- Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical reviewNMR in Biomedicine, 2002
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- Bootstrap Procedures under some Non-I.I.D. ModelsThe Annals of Statistics, 1988