D-dimer in the diagnosis of periprosthetic joint infection: a systematic review and meta-analysis
Authors:
Open Access
- 16 July 2020
- journal article
- review article
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15 (1) , 1-11
Abstract
Background: D-dimer, a coagulation-related indicator, has recently been used as a tool for the diagnosis of periprosthetic joint infection (PJI), but its reliability is uncertain. The purpose of this systematic review and meta-analysis was to explore the accuracy of D-dimer in the diagnosis of PJI after joint arthroplasty. Methods: We systematically searched the MEDLINE, EMBASE, and Cochrane databases for relevant literature about D-dimer in the diagnosis of PJI. QUADAS-2 was used to assess the risk of bias and clinical applicability of each included study. We used the bivariate meta-analysis framework to pool the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the SROC curve (AUC). Univariate meta-regression and subgroup analyses were performed to explore the sources of heterogeneity. Results: We included 8 eligible studies. The pooled diagnostic sensitivity and specificity were 0.82 (95% CI, 0.70–0.89) and 0.70 (95% CI, 0.55–0.82), respectively. The pooled PLR, NLR, and DOR were 2.7 (95% CI, 1.7–4.4), 0.26 (95% CI, 0.15–0.46), and 10 (95% CI, 4–25), respectively. The AUC was 0.83 (95% CI, 0.8–0.86). Serum D-dimer might have higher diagnostic accuracy than plasma D-dimer for PJI (pooled sensitivity: 0.88 vs 0.67; pooled specificity: 0.76 vs 0.61). Conclusions: D-dimer has limited performance for the diagnosis of PJI.Keywords
Funding Information
- National Natural Science Foundation of China (1)
This publication has 42 references indexed in Scilit:
- d-dimer is a significant prognostic factor in patients with suspected infection and sepsisThe American Journal of Emergency Medicine, 2012
- Increasing risk of prosthetic joint infection after total hip arthroplastyActa Orthopaedica, 2012
- New Definition for Periprosthetic Joint Infection: From the Workgroup of the Musculoskeletal Infection SocietyClinical Orthopaedics and Related Research, 2011
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Synovial Fluid D-Dimer Concentration in Foals with Septic Joint DiseaseJournal of Veterinary Internal Medicine, 2011
- D-dimer antigen: current concepts and future prospectsBlood, 2009
- Evaluation of Conventional Microbiological Procedures and Molecular Genetic Techniques for Diagnosis of Infections in Patients with Implanted Orthopedic DevicesJournal of Clinical Microbiology, 2008
- The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessedJournal of Clinical Epidemiology, 2005
- Extravascular coagulation and the plasminogen activator/plasmin system in rheumatoid arthritisArthritis & Rheumatism, 2002
- A comparative evaluation of assays for markers of activated coagulation and/or fibrinolysis: thrombin–antithrombin complex, D‐dimer and fibrinogen/fibrin fragment E antigenBritish Journal of Haematology, 1990