A New, Validated Instrument to Evaluate Competency in Microsurgery: The University of Western Ontario Microsurgical Skills Acquisition/Assessment Instrument [Outcomes Article]
Authors:
- Douglas C. RossDRDouglas C. Ross
- 1 January 2011
- journal article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 127 (1) , 215-222
Abstract
The authors present a model for microsurgery learning as well as a validated instrument to evaluate microsurgical competency. Novice microsurgeons participated in three 3-hour sessions wherein they completed a number of increasingly complex, standardized microsurgical tasks. Performance was recorded and graded using a newly developed University of Western Ontario Microsurgery Skills Acquisition/Assessment (UWOMSA) instrument. The knot-tying and anastomosis modules contained three categories with five-point Likert scales. Each learner's performance was assessed by two blinded surgeons. Reznick's validated global rating scale for operative performance was utilized to establish criterion validity. Within-scale scores were compared via intraclass correlation and between-scale scores with Pearson correlation coefficient. Linear regression was used to evaluate the effect of various predictors on UWOMSA scores. Thirty-seven videos (9.6 hours) were reviewed, including 20 knot-tying sessions and 17 anastomoses. Interrater reliability of UWOMSA was high, with an intraclass correlation coefficient of 0.75 (0.57, 0.87). The intraclass correlation of the global rating scale was 0.79 (0.62, 0.89). Intrarater reliability of the UWOMSA was also high, with an intraclass correlation of 0.69 (0.48, 0.83). The intraclass correlation of the global rating scale was 0.69 (0.47, 0.84). Measures of criterion validity demonstrated strong agreement between UWOMSA and the global rating scale (Pearson correlation coefficient, 0.96; p < 0.001). Measures of construct validity demonstrated that higher scores on the UWOMSA were associated with faster knot tying (p < 0.0001) and higher postgraduate year level (p = 0.05). The UWOMSA instrument performed well in terms of reliability and validity. Further study is planned to assess the instrument's ability to predict microsurgical skills translation to the clinical setting.Keywords
This publication has 26 references indexed in Scilit:
- Management strategies following microsurgical flap failureMicrosurgery, 2009
- A Systematic Review of Skills Transfer After Surgical Simulation TrainingAnnals of Surgery, 2008
- Global Rating Assessment of Skills in Intraocular Surgery (GRASIS)Ophthalmology, 2005
- Objective Assessment of Skills in Intraocular Surgery (OASIS)Ophthalmology, 2005
- Toward reliable operative assessment: the reliability and feasibility of videotaped assessment of laparoscopic technical skillsSurgical Endoscopy, 2004
- Design of a new suture practice card for microsurgical trainingMicrosurgery, 2002
- A Synthetic Model for Microsurgical Training: A Surgical Contribution to Reduce the Number of Animal ExperimentsEuropean Journal of Pediatric Surgery, 1997
- A survey of microsurgery training in the United StatesMicrosurgery, 1990
- Teaching surgeons to operate—Principles of psychomotor skills trainingActa Neurochirurgica, 1987
- Sterilization reversals performed by fellows in training: What success rates can we reasonably expect?Microsurgery, 1987