Five-year clinical follow-up of the STENTYS self-apposing stent in complex coronary anatomy: a single-centre experience with report of specific angiographic indications
Open Access
- 13 April 2018
- journal article
- research article
- Published by Springer Nature in Netherlands Heart Journal
- Vol. 26 (5) , 263-271
Abstract
Objectives We sought to investigate angiographic indications for the use of the STENTYS technique and evaluated the long-term safety and clinical efficacy of the stent. Background Coronary lesions involving complex anatomy, including aneurysmatic, ectatic, or tapered vessel segments often carry a substantial risk of stent malapposition. The self-apposing stent technique may reduce the risk of stent malapposition and therefore improve clinical outcomes. Methods A total of 120 consecutive patients treated with the STENTYS stent were included (drug-eluting stent (DES) n = 101, bare-metal stent (BMS) n = 19). All lesions were scored for angiographic indications for the STENTYS stent, including aneurysms, ectasias, tapering, absolute diameters, bifurcation lesions, and saphenous vein grafts. Off-line quantitative coronary angiography analyses were performed pre-procedure and post-procedure. Five years follow-up was obtained including cardiac death, target vessel myocardial infarction (TV-MI), target vessel revascularisation, stent thrombosis, and the composite endpoint target vessel failure (cardiac death, TV-MI and target vessel revascularisation). Results Angiographic indications for STENTYS use were aneurysm (30%), ectasia (19%), tapering (27%), bifurcation lesions (8%), and saphenous vein graft lesions (16%) and absolute diameters (22%). Mean maximal diameter was 4.51 ± 0.99 mm. At 5‑year follow-up target vessel failure rates were 24.1% in the total cohort (DES 22.8% vs. BMS 33%, p = 0.26). Definite stent thrombosis rate was 3.8% at 5‑year follow-up in this cohort with complex and high-risk lesions (DES 4.5% vs. BMS 0%, p = 0.39). Conclusions Angiographic indications for the use of the self-apposing stent were complex lesions with atypical coronary anatomy. Our data showed reasonable stent thrombosis rates at 5‑year follow-up, considering the high-risk lesion characteristics.Keywords
Funding Information
- AMC received institutional research grants from STENTYS SA France
This publication has 28 references indexed in Scilit:
- Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)Netherlands Heart Journal, 2017
- Lesion Complexity and Outcomes of Extended Dual Antiplatelet Therapy After Percutaneous Coronary InterventionJACC, 2017
- Self-expanding stent for complex percutaneous coronary interventions: A real life experienceCardiovascular Revascularization Medicine, 2016
- A real world single centre experience using the STENTYS self-expanding coronary stentInternational Journal of Cardiology, 2016
- Angiographic predictors of 2‐year stent thrombosis in patients receiving drug‐eluting stents: Insights from the ADAPT‐DES studyCatheterization and Cardiovascular Interventions, 2016
- Comparative Effectiveness and Safety of New-Generation Versus Early-Generation Drug-Eluting Stents According to Complexity of Coronary Artery DiseaseJACC: Cardiovascular Interventions, 2015
- Importance of knowing stent design threshold diameters and post-dilatation capacities to optimise stent selection and prevent stent overexpansion/incomplete apposition during PCIInternational Journal of Cardiology, 2013
- Self-Expanding Versus Balloon-Expandable Stents in Acute Myocardial Infarction: Results From the APPOSITION II StudyJACC: Cardiovascular Interventions, 2012
- The Impact of Patient and Lesion Complexity on Clinical and Angiographic Outcomes After Revascularization With Zotarolimus- and Everolimus-Eluting StentsJACC, 2011
- Value of the SYNTAX Score for Risk Assessment in the All-Comers Population of the Randomized Multicenter LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) TrialJACC, 2010