Background The success of shoulder stabilization with the Latarjet procedure might depend on the size of the bone graft and the positioning of the coracoid at the glenoid. The aim of this study was to quantitatively assess the surface of the coracoid bone graft and to assess its positioning in the en-face view. Method A series of 21 patients (17 men, 4 women, 26.1 ± 6.8 years—9 right, 12 left shoulders) were prospectively included and followed up with CT scans between December 2010 and April 2012 at an average of 2.4 ± 0.7 months postoperatively. The retrospective analysis of the CT scans was performed with Osirix™ software. The coracoid surface was measured (cm2) in the sagittal plane. The positioning in relation to the center of the circumscribed circle of the glenoid was determined in the en-face clock face view of the glenoid. Results The grafts had a mean surface of 1.61 ± 0.51 cm2 (mean ± standard deviation). The coracoid grafts were located between 01:05 hours (32.5°) and 05:33 hours (166.6°). Mean positioning was 02:00 hours (59.8° ± 16.1°) to 04:26 hours (133.0° ± 16.9°). The extent of the grafts was 73.2° ± 14.3°. Discussion The positioning of the coracoid graft on the clock face of the glenoid is situated in the decisive zone of 02:30–04:20 hours. The mean surface of the graft is smaller than expected from anatomical studies, but restores in defect situations bone stock in the potential defect areas at the anterior glenoid rim. Level of evidence Level IV, prospective case series, treatment study.Keywords
This publication has 29 references indexed in Scilit:
- Recurrence after arthroscopic Bankart repair: Is quantitative radiological analysis of bone loss of any predictive value?Orthopaedics & Traumatology: Surgery & Research, 2012
- Correlation of Coracoid Thickness and Glenoid WidthThe American Journal of Sports Medicine, 2012
- Coracoid graft osteolysis after the Latarjet procedure for anteroinferior shoulder instability: a computed tomography scan study of twenty-six patientsJournal of Shoulder and Elbow Surgery, 2011
- An anatomic study of the coracoid process as it relates to bone transfer proceduresJournal of Shoulder and Elbow Surgery, 2011
- Open Latarjet procedure for management of bone loss in anterior instability of the glenohumeral jointJournal of Shoulder and Elbow Surgery, 2011
- Effect of an Anterior Glenoid Defect on Anterior Shoulder StabilityThe American Journal of Sports Medicine, 2009
- Open Shoulder Repair of Osseous Glenoid DefectsThe American Journal of Sports Medicine, 2008
- The instability severity index scoreThe Journal of Bone and Joint Surgery. British volume, 2007
- One hundred eighteen Bristow-Latarjet repairs for recurrent anterior dislocation of the shoulder prospectively followed for fifteen years: Study II—the evolution of dislocation arthropathyJournal of Shoulder and Elbow Surgery, 2006
- Location of the Glenoid Defect in Shoulders with Recurrent Anterior DislocationThe American Journal of Sports Medicine, 2005