Analysis of Influence of Coil Gradient System on Vibration Properties and Acoustic Noise Level Generated by the Low Field MRI Device
Authors:
Open Access
- 1 October 2018
- journal article
- research article
- Published by Walter de Gruyter GmbH in Measurement Science Review
- Vol. 18 (5) , 193-200
Abstract
The paper focuses on investigation of influence of the volume inserted in the scanning area of the magnetic resonance imaging (MRI) device working with a low magnetic field generated by a pair of permanent magnets on vibration and acoustic noise. In addition, its aim is to evaluate the influence of different types of used scan sequences, different settings of slice orientation and scan parameters on the energy and spectral properties of vibration and noise generated by the gradient coil system of the MRI device. Two basic measurements were performed within this work: mapping of sound pressure levels in the MRI device vicinity and parallel acquisition of vibration signals by sensors mounted on the lower and upper parts of the MRI gradient system. The paper next analyzes changes in properties of the vibration signals for the examined person lying in the scanning area compared with the situation of using only the testing phantom. Spectral characteristics of the recorded vibration signals are then analyzed statistically, and compared visually and numerically. The obtained results of the detailed analysis will be used for improvement of noise suppression algorithms applied to a speech signal recorded simultaneously with scanning of the human vocal tract for its 3D modeling.Keywords
This publication has 14 references indexed in Scilit:
- Gradient and shim technologies for ultra high field MRINeuroImage, 2018
- A high‐performance gradient insert for rapid and short‐T2imaging at full duty cycleMagnetic Resonance in Medicine, 2017
- On the accurate analysis of vibroacoustics in head insert gradient coilsMagnetic Resonance in Medicine, 2016
- Asymmetric gradient coil design for use in a short, open bore magnetic resonance imaging scannerJournal of Magnetic Resonance, 2016
- Comparison of mechanical vibration and acoustic noise in the open-air MRIApplied Acoustics, 2016
- A Novel Method for Constructing 3D Geometric Articulatory ModelsJournal of Signal Processing Systems, 2015
- Mapping and Spectral Analysis of Acoustic Vibration in the Scanning Area of the Weak Field Magnetic Resonance ImagerJournal of Vibration and Acoustics, 2014
- A probabilistic MR atlas of the human cerebellumNeuroImage, 2009
- Vibration analysis and testing of a thin-walled gradient coil modelJournal of Sound and Vibration, 2008
- Single point imaging with suppressed sound pressure levels through gradient-shape adjustmentJournal of Magnetic Resonance, 2004