Thermal modeling of directly-oil-cooled permanent magnet synchronous machine
Authors:
- 1 September 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1882-1887
Abstract
The main objective of this paper is to investigate the potential and effectiveness of direct oil cooling of a PMSM. The lumped parameters thermal network (LPTN), the thermostatic FEM model, and Computational Fluid Dynamics (CFD) model are built. The results of modeling are compared. The pros and cons of each modeling technique are briefly discussed. The detailed flow modeling by means of CFD allows precise determination of the cooling possibilities which gives to designer the information required for choosing the optimal volumetric coolant flow.Keywords
This publication has 5 references indexed in Scilit:
- Conjugated fluid-solid heat transfer modeling of a directly-oil-cooled PMSM using CFD2012
- Evaluation of heat transfer characteristic of Aluminum Nitride (AlN) potting compound for the end windings of permanent magnet synchronous machines2011
- Design of Rotating Electrical Machines2008
- Thermal Analysis of Radial-Flux Electrical Machines With a High Power DensityIEEE Transactions on Industrial Electronics, 2008
- Magnetic and thermal performance of a synchronous motor under loss minimization controlIEEE Transactions on Energy Conversion, 2000