The Dixon technique for MRI of the bone marrow
Authors:
- 15 July 2019
- journal article
- review article
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (12) , 1861-1874
Abstract
Dixon sequences are established as a reliable MRI technique that can be used for problem-solving in the assessment of bone marrow lesions. Unlike other fat suppression methods, Dixon techniques rely on the difference in resonance frequency between fat and water and in a single acquisition, fat only, water only, in-phase and out-of-phase images are acquired. This gives Dixon techniques the unique ability to quantify the amount of fat within a bone lesion, allowing discrimination between marrow-infiltrating and non-marrow-infiltrating lesions such as focal nodular marrow hyperplasia. Dixon can be used with gradient echo and spin echo techniques, both two-dimensional and three-dimensional imaging. Another advantage is its rapid acquisition time, especially when using traditional two-point Dixon gradient echo sequences. Overall, Dixon is a robust fat suppression method that can also be used with intravenous contrast agents. After reviewing the available literature, we would like to advocate the implementation of additional Dixon sequences as a problem-solving tool during the assessment of bone marrow pathology.Keywords
This publication has 86 references indexed in Scilit:
- Comparison of Qualitative and Quantitative Evaluation of Diffusion-Weighted MRI and Chemical-Shift Imaging in the Differentiation of Benign and Malignant Vertebral Body FracturesAmerican Journal of Roentgenology, 2012
- Rekonwersja szpiku – obrazowanie fizjologicznych zmian szpiku w codziennej praktycePolish Journal of Radiology, 2012
- MRI of Spinal Bone Marrow: Part 1, Techniques and Normal Age-Related AppearancesAmerican Journal of Roentgenology, 2011
- Fast dixon whole‐body MRI for detecting distant cancer metastasis: a preliminary clinical studyJournal of Magnetic Resonance Imaging, 2011
- MR Imaging of Bone Metastases and Choice of Sequence: Spin Echo, In-Phase Gradient Echo, Diffusion, and Contrast MediumSeminars in Musculoskeletal Radiology, 2009
- Fast dixon‐based multisequence and multiplanar MRI for whole‐body detection of cancer metastasesJournal of Magnetic Resonance Imaging, 2009
- A single‐point dixon technique for fat‐suppressed fast 3D gradient‐echo imaging with a flexible echo timeJournal of Magnetic Resonance Imaging, 2008
- T1‐ and T2‐weighted fast spin‐echo imaging of the brachial plexus and cervical spine with IDEAL water–fat separationJournal of Magnetic Resonance Imaging, 2006
- Useful internal standards for distinguishing infiltrative marrow pathology from hematopoietic marrow at MRIJournal of Magnetic Resonance Imaging, 1997