Intraoperative CT in Spine Surgery
- 26 August 2010
- book chapter
- Published by Springer Nature
- Vol. 109, 169-174
Abstract
In spinal instrumentation the misplacement of screws, cages and rods may cause neurovascular complications. Therefore a large variety of methods have been used in recent years to reduce such complications especially by navigation techniques and intraoperative three-dimensional fluoroscopy. The aim of this study is to answer the question: will intraoperative CT improve the efficiency of the treatment as well as the safety for the patient at the spinal instrumentation? Specific questions were: are the implants placed correctly and has decompression been performed sufficiently? This is a prospective study in 100 patients mostly with degenerative diseases, tumours and trauma. 80 patients were treated by spinal instrumentation. A helical CT (Somatom Emotion 2003) was used, which is firmly bound to the OR table by a track system. 569 implants were used: 159 vertebra body screws and plates, 88 cages, 154 pedicle screws, 73 facet joint screws and 95 rods. There was malpositioning in seven patients (8.75%). 18 of 154 pedicle screws were misplaced, 2 of 88 cages, and 4 of 73 facet joint screws, for a total of 24 (7.6%). Intraoperative CT is a useful tool to check the correct position of the implants used, the extent of decompression and the realignment as early as possible. It therefore reduces second operations. A postoperative CT is no longer necessary.Keywords
This publication has 21 references indexed in Scilit:
- Intraosseous Ultrasound in the Placement of Pedicle Screws in the Lumbar SpineSpine, 2009
- Intraoperative Kontrolle der Pedikelschraubenposition mittels 3‐D‐Bildwandler. Eine prospektive Studie bei der Versorgung thorakolumbaler FrakturenZeitschrift für Orthopädie und Unfallchirurgie, 2009
- Comparison of two novel fluoroscopy-based stereotactic methods for cervical pedicle screw placement and review of the literatureEuropean Spine Journal, 2008
- The Value of Intraoperative Three Dimensional Fluoroscopy in Anterior Decompressive Surgery of the Cervical SpineCentral European Neurosurgery, 2008
- Accuracy of Intraoperative Plain Radiographs to Detect Violations of Intralaminar Screws Placed Into the C2 VertebraeSpine, 2007
- Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidanceEuropean Spine Journal, 2007
- Cervical pedicle screw fixation in 100 cases of unstable cervical injuries: pedicle axis views obtained using fluoroscopyJournal of Neurosurgery: Spine, 2006
- Safety and Efficacy of C2 Pedicle Screws Placed With Anatomic and Lateral C-Arm GuidanceSpine, 2006
- Image-guided spinal surgeryThe International Journal of Medical Robotics and Computer Assisted Surgery, 2006
- Intraoperative evaluation of bone decompression in anterior cervical spine surgery by three-dimensional fluoroscopyEuropean Spine Journal, 2005