Novel Triggered Nocturnal Blood Pressure Monitoring for Sleep Apnea Syndrome: Distribution and Reproducibility of Hypoxia‐Triggered Nocturnal Blood Pressure Measurements
Authors:
Open Access
- 14 July 2016
- journal article
- research article
- Published by Wiley in The Journal of Clinical Hypertension
- Vol. 19 (1) , 30-37
Abstract
Obstructive sleep apnea (OSA) causes blood pressure (BP) surges during sleep, which may lead to increased sleep‐onset cardiovascular events. The authors recently developed a triggered nocturnal BP monitoring system that initiates BP measurements when oxygen desaturation falls below a variable threshold. The distribution and reproducibility of hypoxia‐triggered nocturnal BP parameters compared with those of fixed‐interval nocturnal BP parameters for two consecutive nights in 147 OSA patients (mean age 59.4 years, 86.4% men) were evaluated. The mean and distribution (standard deviation [SD]) of the hypoxia‐peak systolic BP (SBP) were significantly greater than that of the mean nocturnal SBP (mean±SD: 148.8±20.5 vs 123.4±14.2 mm Hg, P<.001). The repeatability coefficient (expressed as %MV) of hypoxia‐peak SBP between night 1 and night 2 was comparable to that of mean nocturnal SBP (43% vs 32%). In conclusion, hypoxia‐peak nocturnal BP was much higher than mean nocturnal BP, and it was as reproducible as mean nocturnal BP.Keywords
Funding Information
- Ministry of Education, Culture, Sports, Science and Technology
This publication has 37 references indexed in Scilit:
- Proposal of a new strategy for ambulatory blood pressure profile-based management of resistant hypertension in the era of renal denervationHypertension Research, 2013
- Obstructive Sleep ApneaHypertension, 2011
- Obstructive sleep apnea syndrome and hypertension: ambulatory blood pressureHypertension Research, 2009
- Short-term and long-term repeatability of the morning blood pressure in older patients with isolated systolic hypertensionJournal Of Hypertension, 2008
- Day–Night Variation of Acute Myocardial Infarction in Obstructive Sleep ApneaJACC, 2008
- Validation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the European Society of Hypertension International ProtocolBlood Pressure Monitoring, 2007
- Prognostic significance of blood pressure measured in the office, at home and during ambulatory monitoring in older patients in general practiceJournal of Human Hypertension, 2005
- Ambulatory Blood Pressure and 10-Year Risk of Cardiovascular and Noncardiovascular MortalityHypertension, 2005
- Reproducibility of ambulatory and clinic blood pressure measurements in elderly hypertensive subjectsJournal Of Hypertension, 1993
- Involvement of the baroreceptor reflexes in the changes in blood pressure with sleep and mental arousal.Hypertension, 1983