Abstract
Weaning from mechanical ventilation is a complex process requiring assessment and interpretation of both objective and subjective clinical parameters. For many years, automated computerised systems for various medical processes, including respiratory management, have been proposed to optimise decision-making and reduce variation amongst clinicians. SmartCare™/PS, available since 2003 as a software application for the EvitaXL ventilator (Drager Medical AG & Co. KG, Lübeck, Germany), is one of the first such ventilator systems to be made commercially available. SmartCare/PS can be described as a knowledge-based weaning system, which adjusts pressure support based on measurement of the patient's respiratory status, specifically the spontaneous respiratory rate, tidal volume and end-tidal carbon dioxide with the aim of optimising the weaning process. The primary proposed advantage of this system is an ability to provide management of ventilatory weaning through continuous physiological monitoring and real-time interventions. The relatively small number of available clinical studies indicate the system is able to deliver appropriate ventilation during pressure support weaning from both short-term and prolonged ventilation. Of potential clinical note, a recent study suggested that use of SmartCare/PS might be associated with useful reductions in the duration of weaning compared to existing clinical practice using weaning protocols. One recently published randomised trial supports this conclusion. However, given the known large variation in international critical care ventilatory practices further randomised trials are desirable.Keywords
This publication has 11 references indexed in Scilit:
- Clinical Use of Amrinone (a Selective Phosphodiesterase III Inhibitor) in Reconstructive SurgeryPlastic and Reconstructive Surgery, 2001
- Comparison of milrinone versus nitroglycerin, alone and in combination, on grafted internal mammary artery flow after cardiopulmonary bypass: Effects of α-adrenergic stimulationJournal of Cardiothoracic and Vascular Anesthesia, 2001
- Effects of epidural anaesthesia on microcirculatory blood flow in free flaps in patients under general anaesthesiaEuropean Journal of Anaesthesiology, 1999
- Effects of Sodium Nitroprusside and Phenylephrine on Blood Flow in Free Musculocutaneous Flaps during General AnesthesiaAnesthesiology, 1999
- Amrinone, a Selective Phosphodiesterase III Inhibitor, Improves Microcirculation and Flap Survival: A Comparative Study with Prostaglandin E1Journal of Surgical Research, 1998
- Adjunctive Measures in Microvascular SurgeryJournal of Reconstructive Microsurgery, 1997
- Effects of Extradural Anesthesia on Microcirculatory Blood Flow in Free Latissimus Dorsi Musculocutaneous Flaps in PigsPlastic and Reconstructive Surgery, 1997
- Inhibition of Vasoconstriction by Phosphodiesterase III Inhibitor Milrinone in Human Conduit Arteries Used as Coronary Bypass GraftsJournal of Cardiovascular Pharmacology, 1996
- Thrombosis and Antithrombotic Therapy in Microvascular SurgeryClinics in Plastic Surgery, 1992
- An experimental in vivo study of the canine internal mammary artery and its response to vasoactive drugsThe Journal of Thoracic and Cardiovascular Surgery, 1988