The Radiation Exposure Associated With Cervical and Lumbar Spine Radiographs
Authors:
- Peter G. WhangPWPeter G. Whang
- Ari JonischAJAri Jonisch
- Andrew HaimsAHAndrew Haims
- Jonathan N. GrauerJGJonathan N. Grauer
- 1 August 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 21 (6) , 409-412
Abstract
Cross-sectional study. To calculate the effective radiation doses of routine anteroposterior (AP) and lateral radiographs of the cervical and lumbar spines. Although plain radiographs are generally used as the initial imaging modality for the evaluation of patients with spinal complaints, the radiation that patients receive during these studies has not been well quantified. The effective radiation dose represents a functional measure of exposure that takes into account the amount of radiation delivered and the radiosensitivity of the exposed organs. Consequently, the effective dose is important to consider from a radiation safety perspective. The imaging practices of our radiology department were reviewed and the effective radiation doses for AP and lateral radiographs of the cervical and lumbar spines were calculated using the following variables: emitted radiation dose, source-to-object distance [SOD], film area, and patient tissue dimensions. Values were obtained from both direct measurements and an examination of the established protocols employed at our institution. The effective doses for AP and lateral cervical radiographs were 0.12 and 0.02 mSv, respectively, whereas the corresponding values for AP and lateral lumbar films were much larger (2.20 and 1.50 mSv, respectively). For comparative purposes, a typical chest x-ray results in a radiation dose between 0.06 and 0.25 mSv. In this investigation, cervical spine films gave rise to radiation doses that are similar to those of chest x-rays. However, lumbar spine radiographs generated effective radiation doses that were approximately an order of magnitude greater than these other studies. In both the cervical and lumbar regions, AP views resulted in significantly greater radiation exposure than corresponding lateral images. The effective radiation doses reported here may prove to be valuable for assessing the relative risks and benefits of spine radiographs to establish appropriate guidelines for their use.Keywords
This publication has 10 references indexed in Scilit:
- Effective doses in standard protocols for multi-slice CT scanningEuropean Radiology, 2003
- Radiation exposure associated with imaging of the chestCancer, 2000
- Breast Cancer Mortality After Diagnostic RadiographySpine, 2000
- Calculation of effective doseMedical Physics, 2000
- The Risk of Carcinogenesis from Radiographs to Pediatric Orthopaedic PatientsJournal of Pediatric Orthopaedics, 2000
- Reducing the Lifetime Risk of Cancer From Spinal Radiographs Among People With Adolescent Idiopathic ScoliosisSpine, 1996
- Dose Distribution at Radiographic Examination of the Spine in Pediatric RadiologySpine, 1996
- Breast Cancer in Women With Scoliosis Exposed to Multiple Diagnostic X RaysJNCI: Journal of the National Cancer Institute, 1989
- Risks of exposure to X-rays in patients undergoing long-term treatment for scoliosis.Journal of Bone and Joint Surgery, 1979
- The concept of the effective dose a proposal for the combination of organ dosesRadiation and Environmental Biophysics, 1975