Stent Implantation of the Arterial Duct in Newborns with a Truly Duct‐Dependent Pulmonary Circulation: A Single‐Center Experience with Emphasis on Aspects of the Interventional Technique
Authors:
- 2 December 2010
- journal article
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 23 (6) , 581-588
Abstract
Introduction: Ductal stenting for pulmonary blood supply in newborns with cyanotic congenital heart disease (CHD) might be a low risk and safe alternative to the surgical aorto‐to‐pulmonary artery (AP) shunt in dual‐source lung perfusion. Ductal stenting in truly duct‐dependent pulmonary circulation has not been evaluated. Methods: Prospective interventional and clinical follow‐up trial. Ductal stenting based on variable access sites, a 2‐wire technique when crossing a tortuous ductus, and use of premounted coronary stents. Primary outcome measures were procedural success and complication rates presented as early and mid‐term results. Results: From 2003–2009, 58 duct‐dependent newborns underwent ductal stenting; 27 of them were truly duct dependent, 20 had pulmonary atresia (PA)/ventricular septum defect or complex CHD, 4 had PA/intact ventricular septum, 2 had PA with Ebstein anomaly, and 1 had PA with tricuspid atresia. Ductal stenting was performed without procedure‐related mortality; 3 of 27 required an acute surgical AP‐shunt (stent migration in 1, acute duct obstruction in 2). During mid‐term follow‐up, 4 of 24 needed an AP‐shunt and two others stent redilation. Three patients died prior to follow‐up surgery (1 unexpectedly at home and 2 due to syndromatic disease). Fifteen patients received staged univentricular palliation, 8 had a biventricular repair, and 1 is awaiting follow‐up operation. Conclusion: Ductal stenting is a feasible, safe, and effective palliation in newborns with truly duct‐dependent pulmonary circulation irrespective of duct morphology. Vasucular access from various locations is important for technical success rate. Ductal stenting is a minimally invasive procedure to achieve adequate pulmonary artery growth for subsequent palliative or corrective surgery. (J Interven Cardiol 2010;23:581–588)Keywords
This publication has 14 references indexed in Scilit:
- Ductal stenting for restricted pulmonary blood flow in neonates: 15 years on but still a very limited place in clinical practiceHeart, 2008
- Axillary artery access for cardiac interventions in newbornsAnnals of Pediatric Cardiology, 2008
- Stenting the neonatal arterial ductExpert Review of Cardiovascular Therapy, 2007
- Stenting of the arterial duct in newborns with duct-dependent pulmonary circulationHeart, 2007
- Catheterization in neonates with pulmonary atresia with intact ventricular septumCatheterization and Cardiovascular Interventions, 2006
- Risk factors for augmentation of the flow of blood to the lungs in pulmonary atresia with intact ventricular septum after radiofrequency valvotomyCardiology in the Young, 2005
- Initial results and medium-term follow-up of stent implantation of patent ductus arteriosus in duct-dependent pulmonary circulationJACC, 2004
- Stent implantation in the ductus arteriosus for pulmonary blood supply in congenital heart diseaseCatheterization and Cardiovascular Interventions, 2004
- Stenting the neonatal arterial duct in duct-dependent pulmonary circulation: new techniques, better resultsJACC, 2004
- Stent implantation of the arterial duct in newborns with duct-dependent circulationEuropean Heart Journal, 1998