Selective Detection of Target Volatile Organic Compounds in Contaminated Humid Air Using a Sensor Array with Principal Component Analysis
Open Access
Abstract
We investigated selective detection of the target volatile organic compounds (VOCs) nonanal, n-decane, and acetoin for lung cancer-related VOCs, and acetone and methyl i-butyl ketone for diabetes-related VOCs, in humid air with simulated VOC contamination (total concentration: 300 μg/m3). We used six “grain boundary-response type” sensors, including four commercially available sensors (TGS 2600, 2610, 2610, and 2620) and two Pt, Pd, and Au-loaded SnO2 sensors (Pt, Pd, Au/SnO2), and two “bulk-response type” sensors, including Zr-doped CeO2 (CeZr10), i.e., eight sensors in total. We then analyzed their sensor signals using principal component analysis (PCA). Although the six “grain boundary-response type” sensors were found to be insufficient for selective detection of the target gases in humid air, the addition of two “bulk-response type” sensors improved the selectivity, even with simulated VOC contamination. To further improve the discrimination, we selected appropriate sensors from the eight sensors based on the PCA results. The selectivity to each target gas was maintained and was not affected by contamination.Keywords
This publication has 38 references indexed in Scilit:
- Nonanal gas sensing properties of platinum, palladium, and gold-loaded tin oxide VOCs sensorsSensors and Actuators B: Chemical, 2013
- Application of the Electronic Nose Technique to Differentiation between Model Mixtures with COPD MarkersSensors, 2013
- Effects of High-Humidity Aging on Platinum, Palladium, and Gold Loaded Tin Oxide—Volatile Organic Compound SensorsSensors, 2010
- Breath gas aldehydes as biomarkers of lung cancerInternational Journal of Cancer, 2010
- Diagnosing lung cancer in exhaled breath using gold nanoparticlesNature Nanotechnology, 2009
- Application of a sensor system for determining the kind and quantity of two component VOC mixtures in air after the use of solventsJournal of Environmental Monitoring, 2009
- Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot studyThorax, 2009
- Preparation of total VOC sensor with sensor-response stability for humidity by noble metal addition to SnO2Journal of the Ceramic Society of Japan, 2009
- Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor arrayThorax, 2007
- Evaluation of response characteristics of resistive oxygen sensors based on porous cerium oxide thick film using pressure modulation methodSensors and Actuators B: Chemical, 2006