Retinal vascular and structural changes are associated with amyloid burden in the elderly: ophthalmic biomarkers of preclinical Alzheimer’s disease
Authors:
- S.Mojtaba GolzanS.Mojtaba Golzan
- Kathryn GoozeeKathryn Goozee
- Dana GeorgevskyDana Georgevsky
- Alberto AvolioAlberto Avolio
- Pratishtha ChatterjeePratishtha Chatterjee
- Kaikai ShenKaikai Shen
- Vivek GuptaVivek Gupta
- Roger ChungRoger Chung
- Greg SavageGreg Savage
- Carolyn F. OrrCarolyn F. Orr
- Ralph N. MartinsRalph N. Martins
- Stuart L. GrahamStuart L. Graham
Open Access
- 1 March 2017
- journal article
- research article
- Published by Springer Nature in Alzheimer's Research & Therapy
- Vol. 9 (1) , 1-9
Abstract
Retinal imaging may serve as an alternative approach to monitor brain pathology in Alzheimer’s disease (AD). In this study, we investigated the association between retinal vascular and structural changes and cerebral amyloid-β (Aβ) plaque load in an elderly cohort. We studied a total of 101 participants, including 73 elderly subjects (79 ± 5 years, 22 male) with no clinical diagnosis of AD but reporting some subjective memory change and an additional 28 subjects (70 ± 9 years, 16 male) with clinically established AD. Following a complete dilated ocular examination, the amplitude of retinal vascular pulsations and dynamic response, retinal nerve fibre layer thickness and retinal ganglion cell layer (RGCL) thickness were determined in all patients. Systemic blood pressure and carotid-to-femoral pulse wave velocity were measured. The elderly cohort also underwent magnetic resonance imaging and 18F-florbetaben (FBB)-positron emission tomographic amyloid imaging to measure neocortical Aβ standardised uptake value ratio (SUVR), and this was used to characterise a ‘preclinical’ group (SUVR >1.4). The mean FBB neocortical SUVR was 1.35 ± 0.3. The amplitude of retinal venous pulsations correlated negatively with the neocortical Aβ scores (p < 0.001), whereas the amplitude of retinal arterial pulsations correlated positively with neocortical Aβ scores (p < 0.01). RGCL thickness was significantly lower in the clinical AD group (p < 0.05). The correlation between retinal vascular changes and Aβ plaque load supports the possibility of a vascular component to AD. Dynamic retinal vascular parameters may provide an additional inexpensive tool to aid in the preclinical assessment of AD.Keywords
Funding Information
- National Health and Medical Research Council
- Alzheimer's Australia Dementia Research Foundation
- Hillcrest Foundation
- Rebecca L. Cooper Medical Research Foundation
- Anglican Retirement Villages
- ARV Aged Care Foundation
This publication has 51 references indexed in Scilit:
- Retinal vascular biomarkers for early detection and monitoring of Alzheimer’s diseaseTranslational Psychiatry, 2013
- Glaucoma, Alzheimer Disease and Other Dementia: A Longitudinal AnalysisOphthalmic Epidemiology, 2012
- Brain Imaging in Alzheimer DiseaseCold Spring Harbor Perspectives in Medicine, 2012
- Alzheimer’s Disease: The Challenge of the Second CenturyScience Translational Medicine, 2011
- Retinal vascular caliber and risk of dementiaNeurology, 2011
- Identification of amyloid plaques in retinas from Alzheimer's patients and noninvasive in vivo optical imaging of retinal plaques in a mouse modelNeuroImage, 2011
- Endothelial Nitric Oxide Modulates Expression and Processing of Amyloid Precursor ProteinCirculation Research, 2010
- Retinal microvascular abnormalities and cognitive declineNeurology, 2009
- β-Amyloid, Blood Vessels, and Brain FunctionStroke, 2009
- Arterial Pulse Wave Velocity and Cognition With Advancing AgeHypertension, 2009